Installing the new water heater (cont’d) – Reliance Water Heaters 184123-000 User Manual

Page 14

Advertising
background image

“Fuel” Conversion Instructions

From Natural Gas To Propane

(L.P.) Gas (cont’d)

Step 21. Replace the outer door if not replaced in step 17.

Step 22. Remove adhesive label found in conversion kit

and place next to rating plate. Mark label indi-

cating for which type gas the water heater is

now equipped.

“Fuel” Conversion Instructions

From Propane (L.P.) Gas To

Natural Gas

To convert from Propane (L.P.) gas to Natural gas, follow

the “Fuel” Conversion Instructions From Natural Gas to

Propane (L.P.) Gas” section except in Step 5, use orifice

“E”, marked “NAT.”. In Step 6 use pilot orifice “G”, brass

color and in Step 8 turn control screw “B” in Figure 4

clockwise ( ) to stop. Screw must be in “OUT” posi-

tion for Natural gas.

See “Instruction Label” for orifice sizes.
Maximum Supply Pressure:

10.5

″ W.C. For Nat. Gas.

13

″ W.C. for Propane (L.P.) Gas

Minimum Supply Pressure

5

″ W.C. for Nat. Gas.

11

″ W.C. For Propane (L.P.) Gas

Installing the New Water Heater (cont’d)

“B”

“A” GAS CONTROL

KNOB

TEMPERATURE

ADJ. DIAL

OUT FOR NATURAL

IN FOR PROPANE (L.P.)

Figure 4

PLASTIC CAP

MANIFOLD

PILOT TUBING

THERMOCOUPLE

NUT “K”

NUT “J”

NUT “H”

Figure 5

BRACKET

MANIFOLD

BURNER

“D”

“E”

Figure 6

14

WARNING

Hotter water increases the risk of scald injury. Before

changing temperature setting see the “Temperature

Regulation” section in this manual.

INLET

GAS

LINE

PILOT TUBING

“G”

“F”

Figure 7

Advertising