Outputs, Inputs, Pre l iminar y – Runco QUANTUM Q-750D User Manual

Page 25

Advertising
background image

Controls and Functions

Q-750d Series Installation/Operation Manual

9

PRE

L

IMINAR

Y

Outputs

1.

HDMI Out
Connect this to the DHD Input on the Q-750d (see Figure 2-2).

2.

Display Control
Connect this to the RS-232 input on the Q-750d, using the provided communication
cable.

3.

TRIGGERS
Connection for up to three (3), 12-volt trigger-controlled devices such as retractable
screens, screen masks or a CineWide with AutoScope system. Output current is
limited to 250 milliamperes (mA).

Inputs

4.

USB
A standard, USB Series “B” connection to a personal computer. (For future use.)

5.

HDMI 1 / HDMI 2 (Digital)
HDCP-compliant digital video inputs for connecting an HDMI or DVI source.

6.

HD1 / HD2 (5 x Analog BNCs)
Two inputs (five BNCs per input) for connecting standard-definition (SD = 480i/576i),
enhanced-definition (ED = 480p/576p) or high-definition (HD = 720p/1080i/1080p)
component video sources, or RGBHV sources such as personal computers.

7.

Component / SCART (5 x RCA connectors)
SD/HD input for connecting SDTV, EDTV or HDTV component video sources, or
RGBHV sources. Also provides RGB input for SCART RGBS sources.

8.

Video
Standard, composite video input for connecting a VCR, camcorder or other
composite video source. Also provides composite sync input for SCART RGBS
sources.

9.

S-Video 1 / S-Video 2
Two, standard S-Video inputs for connecting a DVD player, satellite receiver or Super
VHS (S-VHS) VCR.

10. IR

Wired input from a Niles- or Xantech-compatible, infrared (IR) repeater system. It is a
3.5-mm, mini phono jack, wired as follows:
Ring = No connection
Tip = IR Input
Sleeve = Ground

11. RS-232 / RS-485

A female, 9-pin D-sub connector for interfacing with a PC or automation/control
system. (Currently, only RS-232 interface is supported.)

12. MAIN AC FUSE

This is the main AC input fuse (5mm x 20mm, 500 mA, 250V slow-blow).

13. MAIN POWER SWITCH

Disconnects or applies power to the DHD Controller.

14. POWER INPUT (100 to 240 VAC)

Connect the DHD Controller to power here.