Intelligent Flag I/II

V600-HA

Power Supply Voltage

Do not impose any voltage exceeding the rated voltage range. Doing
so, or applying alternating current (100 VAC) may cause the product
to explode or burn.

Load Short-circuiting

Do not short-circuit the load connected to the product or connect to
the power supply. Doing so may cause the product to explode or
burn.

Wiring

Avoid wiring mistakes such as incorrect polarity in the power supply.
Wiring mistakes may cause the product to explode or burn.

Correct Use

Grounding

The FG line is provided for grounding to the earth. When using the
Amplifier in an environment where it is exposed to large amounts of
noise or if the V600-HA

@91/-HA@81/-HA@92 Amplifier malfunctions,

provide a Class-3 ground (ground resistance of 100

Ω or less). Note

that sharing the grounding wire with other equipment or grounding to
the beam of a building will adversely affect the grounding effect.

Mounting

Amplifier Spacing
When installing V600-HA

@91/V600-HA@81/V600-HA@92 Amplifi-

ers in a row, provide a minimum space of 10 mm between Amplifiers
in order to prevent them from being affected by the heat produced by
each Amplifier.

When housing the Amplifiers in a box, provide a fan or ventilation
opening for radiating the heat.

When wiring power cables, which carry large current such as motor
drive cables, near the V600-HA

@91/81/92 Amplifiers, conduct neces-

sary tests to make sure that the installation conditions are fully satis-
fied.

I/O Interface Requirements

1. The TRG input must be 10 ms min.
2. The INHIBIT input must be 20 ms min.
3. Minimum of 5 ms is required as the transfer time of the Read/

Write Selection Input (W/R).

4. The read data output must be read after the Normal End Output is

set to ON.

Connecting the Sensor

Hold the black part of the connector, line up the notch and push it in
until it clicks.

Compatibility with the SRAM Memory
Type Data Carrier

1. If the Data Carrier is stationary in the transmission area for a long

time when using the V600-HA

@91/81 in the AUTO mode, or when

using the V600-HAR92, it will drastically reduce the battery life.
Therefore, stop the oscillation in the sensor either by turning off
the power of the V600-HA

@91/81/92 Amplifier or by setting the

Inhibit input to ON.

2. Use a Data Carrier that has the oscillation frequency of 530 kHz.

Note that the following models manufactured before February
1991 cannot be used.
V600-D2KR01

V600-D2KR02

Precautions When Using the AUTO
Mode

If transmitting to the Data Carrier while it is traveling under the AUTO
mode, conduct tests to make sure that the travel speed and installa-
tion conditions are fully satisfied.

V600-HA

†91/81/92

Other equipment

FG

Less than 100

V600-HA

†91/81/92

Other equipment

FG

Less than 100

OK

NG

10 mm min.

V600-HA

†91/81/92