Step One 

Specifications: 
Accuracy:  

± 5 mm in water 

Repeatability:  

± 2 mm in water 

Extreme orientation:  ±20° from vertical 
Specific Gravity:  

0.8 minimum 

Contact type:  

(1) SPST (reed) 

Contact rating:  

50 VA @ 0.5A 

Contact output:  

Selectable NO or NC 

Temperature range:   F: ‐40° to 176° / C: ‐40° to 80° 
Pressure: 

10 psi (0.7 bar) 

Sensor rating: 

NEMA 6 (IP68) 

Sensor material:  

LV‐510: Polypropylene 

 

LV‐511: Polyvinylidene Fluoride 

Wire jacket material:  LV‐510: PVC 
 

LV‐511: TFE 

Wire type: 

2‐conductor 

Wire length: 

2’ (61 cm) 

Mounting threads:   1/8" NPT 
Classification:  

General purpose, CE 

Installation: 

1. Switches should be installed rigidly so the float or 

floats  are  free  to  move  as  the  liquid  level 
changes. 

2. Switches  should  be  mounted  in  a  tank  area  free 

of  severe  turbulence  or  protected  from  such 
turbulence  by  appropriate  and  adequate  slosh 
shields. 

3. Vertical  switch  stems  should  be  vertical  for  best 

results,  but  satisfactory  operation  is  possible  in 
most  liquids  with  the  stem  at  up  to  a  20°  angle 
from vertical. 

4. Care  should  be  taken  that  switches  are  always 

operated within electrical ratings. 

5. Orientation  for  switches  can  be  changed  from 

normally  open  to  normally  closed  dry  or  vice 
versa by removing the float and reversing it in the 
stem. 

 

Dimensions: 

 

Components: 

Part 

Number 

Body 

Material 

Cable 

Material 

Thread 

LV‐510 

PP 

PVC 

1/8” NPT

LV‐511 

PVDF 

TFE 

1/8” NPT

 

Switch Rating: 

Reed Switch Rating 

Max. Resistive Load 

VA 

Volts  Amps (AC)  Amps (DC)

50 

0‐50 

0.5 

0.5 

120 

0.4 

0.4 

240 

0.2 

0.2 

Top  Wall  Installation:    Omega  Engineering  LV‐510  series  switch  may  be  installed  through  the  top  wall  of  a 
tank.  Because the thread of the sensor is very small (1/8”), finding standard fittings may be difficult.  In lieu of 
standard fittings, one suggestion is to use a larger pipe, such as ½”.  Place a cap or plug on the end of the pipe 
and tap a 1/8” thread into the end.  Secure the other end of the pipe to the top of the tank or to a clamp.  For 
pipes longer than 2’, be sure to cleanly extend the cable (splice) so that the connection is not exposed to the 