Oasis Concepts Diesel and AC Heating System for Recreational Vehicles and Yachts User Manual

Page 67

Advertising
background image

Section 9, Installing the Distribution Module

supply. The module contains a red and black wire to connect
this pump. The pre-heat switch on the remote control panel
will activate this pump. See Figure 9-5: Engine heat/pre-heat

system plumbing.

Figure 9-5 Engine Heat / Pre-heat System Plumbing.

The pre-heat pump wires are capped off to prevent

accidental shorting. The pre-heat switch on the remote will
turn on power to the wires.

The Distribution module contains two connections on the

side panel to connect to the Oasis™ Heating Module. The
“Inlet from Heater” is connected to the hot coolant supply

outlet on the Oasis™ Heating Module. The “Outlet to Heater”
is connected to the cold coolant return inlet on the Oasis™
Heating Module. It is recommended to use minimal ¾” ID
hose for this connection. See Figure 9-6: Connecting to the
OASIS heating module.

International Thermal Research

9-5

Advertising