Product description 2. starting operations – Omega Engineering PSW2000 User Manual

Page 3

Advertising
background image

3

1. Product Description

2. Starting operations

Intended Applications
-

The dual pressure switch monitors system pressures and has up to two switching outputs

and one analog output.

-

According to DESINA

standard

-

The instruments must only be installed in systems where the maximum pressure Pmax is not

exceeded (according to the values on the type label).

-

Attention: This device is not designed to be used as the only safety relevant element in

pressurized systems according PED 97/23/RC

Only install or uninstall the device when depressurized!
-

Mount the pressure switch from bottom to the fitting with a wrench hex 36 (1/4 ) resp. 19

with 45 Nm torque.

-

Electrical connection depends on the type of pressure switch (see type label) according to the

chart below.

Electrical

connections

PSW3000

Dimensions (in mm)

Plug

M 12 x 1,

4-pin

Model with 1

switching output

Model with 2

switching outputs
(DESINA

)

Model with 1 switching

output and 1 analog output

Pin 1

(15...32 V DC)

(15...32 V DC)

(15...32 V DC)

Pin 2

-

SP2 (0,5 A max.)

analog

Pin 3

0 V

0 V

0 V

Pin 4

SP1 (0,5 A max.)

SP1 (0,5 A max.)

SP1 (0,5 A max.)

PSW2000.qxp 6/12/2008 10:37 AM Page cov-5