General Parts Replacement

HIGH VOLTAGE WARNING - This equipment is supplied with line voltage from a
standard wall socket. Use standard precautions in working on it with line voltage
applied. Failure to practice normal electrical safety precautions can cause
electrical shock, personal injury or property damage.

9.

Unplug the red terminal (3), brown
terminal (2) and black terminal (1) wires
from the selector switch by pushing a
paper clip (straightened) under the wire
into the switch while pulling on the wire
lightly.

10. Remove the white motor wire from the

power supply board line neutral
connection.

11. Remove the motor and replace it with the

new motor.

12. Reverse the above steps to replace the

motor.

13. It is important that the motor isolators are

installed correctly and are seated as
designed. Contacts on side of insulator
should fit over motor bearing bracket.
Motor and isolators must fit securely.