Γ= 20 ° γ = 20 – Opticon OPR 3001 User Manual

Page 14

Advertising
background image

Opticon

OPR 3001

Specifications Manual



14

7.3.3.

Tilt Angle

γ = ±20°

γ

20

°

γ

20

°

Figure 6: Tilt angle

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

Distance:

60 mm from the edge of the scanner

Label:

Pitch Angle, Skew Angle, Dead Zone
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39, Quiet Zone = 10 mm
N/W Ratio = 1:2.5
Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Angle:

Pitch Angle:

Skew Angle β = +15°, Tilt Angle γ = 0°

Tilt Angle:

Pitch Angle α = 0°, Skew Angle β = +15°

Skew Angle, Dead Zone:

Pitch Angle α = 0°, Tilt Angle γ = 0°

Curvature: R

=