Opticon LPR5627 User Manual

Page 56

Advertising
background image

Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount

Scanner

Page 52

22. Positive & Negative Bar Codes

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

-[8-

V4

Positive bar code only

(black bars/white spaces)

-W3-

V2

Both positive & negative bar

code

-W5-

%

23. Setting the Trigger Function

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

-[8-

S7

Disable the trigger function

/ Red scanning light is ON

continuously (Factory Set)

-T8-

S8

Enable the trigger function /Red

scanning light is OFF until trigger

is activated or “pulled”

-T9- %

Z

Activate the trigger; turns on the

red scanning light

Use

Computer Command

The Trigger function is disabled in the default setting. This means that the red scanning light is “ON”

continuously and the scanner is always ready to read. For some applications, you may wish to activate

the scanner only at a specific time. This can be done by enabling the Trigger function. Once in the

“Trigger Enabled” mode, the red scanning light is OFF until the trigger is activated or “pulled.” Either a

hardware trigger or a software trigger pulse may be used to activate the scanner.

The hardware trigger is actuated by pulling Pin #1 (on the standard 9-pin mini-DIN connector) LOW.

The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host.

(See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is

activated.)

Advertising