5

WHAT CAN YOU VIEW?

1) "A sub B" - If you have selected the "A sub B" mode, pressing "view" shows:

A) The net result of subtracting input B from input A. Pulses on input B will subtract (count down). Pulses on input A

will add (count up) if "reset to 0" is selected, if "set to preset" is selected, input A will subtract (count down).

B) The rate of input A.

2) "A add B" - If you have selected "A add B" mode, pressing "view" shows:

A) The net result of adding "A" and "B" inputs. Pulses on input B will add (count up). Pulses on input A will add

(count up) if "reset to 0" is selected, if "set to preset" is selected input A will subtract (count down).

B) The rate of input A.

3) "A sep B" - If you have selected " A sep B" mode, pressing "view" shows:

A) The total counts of input A. If "reset to 0" is selected A counts up, if "set to preset" is selected A will count down.
B) The rate of input A.
C)* The total counts of input B. B will always count up.

NOTE: In "A sep B" mode, B can be used in 3 ways:

1) As a separate totalizing counter
2)** As a Batch Total Counter for input A
3)** As a Grand Total Counter for input A

NOTE:
* All decimal points are inverted when "B total" is being displayed.
** See below on how to modify for Batch Count and "B" as a Grand Total Counter.

MILLIVOLT INPUT OPTION

JUMPER SELECTIONS

OUTPUT JUMPER SELECTIONS

FUNCTION

"A" RELAY
N.C. OUTPUT

"B" RELAY
N.C. OUTPUT

"A" PRESET
TRANSISTOR (NPN)

"B" PRESET
TRANSISTOR (NPN)

"B" AS BATCH
COUNTER

"B" AS GRAND
TOTAL COUNTER

MODIFICATION

CUT JUMPER
AT "A" "B" TO "2"

CUT JUMPER
AT "D" "E" TO "4"

CUT JUMPER
AT "A" "C" TO "2"

CUT JUMPER
AT "D" "F" TO "4"

SELECT JUMPER
"A SEP B" "H" TO "G"

SELECT CONNECT
"A SEP B" PULSES TO
"A" & "B"

BOTTOM VIEW AT TERMINAL

D

E

G

H

20192

12 11 10 9 8 7 6 5 4 3 2 1

L

4

A

B

2

F

C

J4

J5

J6

J3

J1

J2

CR1

R3

C8

R7

R5

R4

U1

CR2

REV

20229

CR6

CR3

U3

P1

R10

R6

C6

C7

CR4

CR5

C4

R2

R1

C3

C5

U2

U4

U6

U5

R8

R9

C1

C2

C9

B

If the unit has the millivolt input bd.# 20229, A & B inputs can be
separately solder jumper programmed to accept either a low milli-
volt or 4-30 V input. Each unit shipped is programmed according
to part number. If solder jumpers are made, the part number
should be modified to reflect the changes made

C=CLOSE, O=OPEN

4-30V INPUT

Millivolt INPUT

Input A

J1-O, J2-C, J3-O

J1-C, J2-O, J3-C

InputB

J4-O, J5-C, J6-O

J4-C, J5-O, J6-C

*

*

* The unit must be removed from the case to access jumpers C & F, all

other jumpers can be accessed by removing the plastic extender.

NOTE: All three pads at jumpers 2 and 4 are connected.