General specifications – Omega LDP-124 User Manual

Page 7

Advertising
background image

Page : 6

OUTPUTS

SERIAL OUTPUT . . . . . . . Output intended for transmission to the

remote display fitted with a clock
display as a slave clock display.

Signal . . . . . . . . . . . . . . . . RS422 level 1200 baud fixed rate. One

transmission each second while
showing real time or run time.

String . . . . . . . . . . . . . . . . . Transmits --NUL--(CR)

or --NUL--NUL--(CR) when setting time
or entering alarm state.

Data string

Standard mode . . . . . HH.MM.SS for 6 decade version.

HH.MM or MM.SS for 4 decade version.

Newport mode . . . . . . HHM.MS.S for 6 decade version.

HHM.M or MMS.S for 4 decade version.

Character length . . . . . . . . One start bit, 8 data bits no parity and

one stop bit.

Handshake . . . . . . . . . . . . No handshake : one data string

transmitted each second.

EXCITATION VOLTAGE OUTPUT

Vexc . . . . . . . . . . . . . . . . . +15 Vdc ±20%. @100 mA. max.
Ripple . . . . . . . . . . . . . . . . 100 mVac 50/60 Hz.

ENVIRONMENTAL

Temperature
Operating . . . . 0 to +50 ºC (32 to 122 ºF).
Storage . . . . . . -20 to +85 º C (-4 to 185 ºF).
Relative humidity . . . . . . . . 0 to 85 % not condensed.
Protection . . . . . . . . . . . . . IP65. (Front part only).

MECHANICAL

Dimensions . . . . . . . . . . . . See table in page 13.
Panel cut out . . . . . . . . . . . See table in page 13.
Depth . . . . . . . . . . . . . . . . . See table in page 13.
Weight . . . . . . . . . . . . . . . . See table in page 13.
Case material . . . . . . . . . . . Aluminium extruded.
Finished . . . . . . . . . . . . . . . Anodized, black colour.

ELECTRICAL

Standard power supply . . . 115 Vac. ±10% 50 / 60 Hz.

(230 Vac optionally)

Consumption . . . . . . . . . . . See table in page 13.

5.- GENERAL SPECIFICATIONS

DISPLAY

Type . . . . . . . . . . . . . . . . . 4 or 6 digits, 7 segments, red or green LED.
Height digit . . . . . . . . . . . . 57 (2.3") or 100 mm. (4")
Range máx. . . . . . . . . . . . . 99 : 59 or 99 :59 : 59
Brightness . . . . . . . . . . . . . Set by switch for 25%, 50%, 75%

or 100% (normal).

REAL TIME CLOCK

.

Type . . . . . . . . . . . . . . . . . 59 mm 59 ss (model C0)

12/24 hours selectable

Time setting . . . . . . . . . . . . By volt free contact closure inputs

seconds reset, minutes advance
and hours advance.

Time accuracy . . . . . . . . . . ±1 minute per month.
Power down . . . . . . . . . . . . Maintains time for minimum 2 years

without mains power.

RUN TIME CLOCK

Type . . . . . . . . . . . . . . . . . 99 mm 59 ss, 99 hh 59 mm

or 99 hh 59 mm 59 ss

Timer resolution . . . . . . . . . 1 second.
Timer uncertainty . . . . . . . . 1 second max. per start/stop sequence.
Timer memory . . . . . . . . . . Run time maintained for 2 years minimum

but not updated with mains removed.

Alarm . . . . . . . . . . . . . . . . . One minute or one second resolution

(one minute only on model C2) set by

external closure inputs.
Alarm enable . . . . . . . . . . . Controlled by internal switch.
Alarm output . . . . . . . . . . . Optically isolates transistor switch

30 V / 30 mA capacity.

Alarm indication . . . . . . . . . Clock stop, display flashes and alarm

output activates.

Initialization . . . . . . . . . . . . By operation of one or more the

control inputs.

CONTROL LINES

Type . . . . . . . . . . . . . . . . . Three inputs sharing one common return.
Threshold . . . . . . . . . . . . . Rising : +2.3 V min., +3.6 V max.

Falling : +0.9 V min., +2.5 V max.

Signal hysteresis . . . . . . . . 0.4 V minimum.
Maximum signal . . . . . . . . . ±30 V.
Loading . . . . . . . . . . . . . . . 100 K

to common for +5 V signal

18 K

loading beyond +5/-0.6V.

Load . . . . . . . . . . . . . . . . . 1 K

±5% load may be internally

jumpered to common or to the excitation
supply for each control line.

Response time . . . . . . . . . . 200 mS maximum: internally

debounced for contact closure inputs.

Active level . . . . . . . . . . . . . Internally jumpered to be active either with

low level/falling edge or high level/rising
edge inputs independently for each
control line.

CONTROL MODES

Type . . . . . . . . . . . . . . . . . The operating mode depends on

interlinking of the three control lines.

One control . . . . . . . . . . . . To reset and run when active and stop

when inactive.

Two controls . . . . . . . . . . . One to run when active and stop when

inactive and the other to reset.

Two controls . . . . . . . . . . . One to alternately start and stop and the

other to reset.

Three controls . . . . . . . . . . One to start, one to stop and one to

reset.