Scanning configurations – Omnitron Systems Technology RS-232 User Manual

Page 53

Advertising
background image

47

Scanning Configurations

One common problem is incorrect configuration setup. You may be trying

to read a bar code with the check digit enabled, but the bar code was printed

without it. The default settings for the reader are the most frequently-used

parameters. If these work, use them. That way, when someone inadvertently

changes the settings, they can be reset by entering the return to default codes.

If you must use different settings, it is advisable to make a master sheet with

the desired configuration keystrokes in the proper order. The operator can

then enter the sequential order to return to the original configuration.

Is the proper bar code symbology enabled?

Each symbology is individually enabled or disabled. It is sometimes desirable

to enable only those that will be used, thereby eliminating any errors due to

the operator scanning the wrong bar code symbol.

Does the selected symbology format options match the symbol?

The scanned data from each bar code symbology can be restricted to elimi-

nate the scanning of unwanted symbols. The restrictions are individually set

for each symbology.

Is the reader able to read bar codes?

The Omni is available in magnetic stripe-only and bar code-only versions,

as well as in a combo version that read both bar codes and magnetic stripes.

Please check the model number with your supplier to make sure the Omni is

configured to read the media you want it to read.

Advertising