Electrical adjustment instructions, Test equipment required, How to make service remote control unit – Sylvania SRT2232X User Manual

Page 14: How to set up the service mode, +b adjustment

Advertising
background image

5-1

L6650EA

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note:
"CBA" is abbreviation for "Circuit Board Assem-
bly."

NOTE:

Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.

Test Equipment Required

1. NTSC Pattern Generator (Color Bar W/White

Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)

2. DC Voltmeter
3. Oscilloscope: Dual-trace with 10:1 probe,

V-Range:0.001~50V/Div,
F-Range: DC~AC-60MHz

4. Plastic Tip Driver
5. Remote control unit: Part No. N0138UD or N0139UD
6. DC power supply 13.2V/5A

How to make Service remote control unit:

1. Prepare normal remote control unit. (Part No.

N0138UD or N0139UD) Remove 3 Screws from
the back lid. (Fig. 1-1)

2. Added J1 (Jumper Wire) to the remote control CBA.

(Fig. 1-2)

Notes:
1. The service remote control unit that be made in

above method is usable in the electrical adjustment
of the following models.
SRT2313/2319, SRT2213B/2219B, SRT2227X,
SRT2223X, SRT2223B, SRT2232X, SRT2220P
SRT4127P

2. The attached remote control unit can not be used

as service remote control unit.

How to set up the service mode:

Service mode:

1.

Use the service remote control unit.

2.

Turn the power on. (Use main power on the TV
unit.)

3. Press "SLEEP" button on the service remote con-

trol unit. Version of micro computer will display on
the CRT. (Ex: 054-0.05)

4.

Check the display on the lower left is "3815" and if
it is not "3815," set it at "3815" according to "2. Ini-
tial Setting."

1. +B Adjustment

Purpose: To obtain correct operation.

Symptom of Misadjustment: The picture is dark and
the unit does not operate correctly.

Note:TP601, TP300(GND), VR661 --- Main CBA
1. Connect DC Volt Meter to TP601 and TP300(GND).
2. Adjust VR661 so that the voltage of TP601 becomes

+132±0.5V DC.

SCREWS

REMOTE CONTROL UNIT

Fig. 1-1

J 1

Fig. 1-2

REMOTE CONTROL CBA

Test Point

Adj. Point

Mode

Input

TP601(+B)

TP300(GND)

VR661

---

---

Tape

M. EQ.

Spec.

---

DC Voltmeter

+132±0.5V DC.