H. position adjustment, V. size adjustment, V. position adjustment – Sylvania SRT2232X User Manual

Page 18: U-pedestal adjustment

Advertising
background image

5-5

L6650EA

8. H. Position Adjustment

Purpose: To obtain correct horizontal position of
screen image.

Symptom of Misadjustment: If H. Position is incor-
rect, horizontal position of image on the screen may
not be properly displayed.

Note: Use service remote control unit

1. Operate the unit for at least 20 minutes.

2. Enter the Service mode. (See page 5-1)

3. Receive the monoscope pattern.

4. Press "8" button on the remote control unit.

"H-P" is indicated.

5. Press "CH o/p" buttons on the service remote

control unit so that the monoscope pattern will be
90±5% of display size and the circle is round.

6. Turn the power off and on again. (Main power but-

ton on the TV unit.)

9. V. Size Adjustment

Purpose: To obtain correct vertical width of screen image.

Symptom of Misadjustment: If V. Size is incorrect, vertical
size of image on the screen may not be properly displayed.

Note: Use service remote control unit.

1. Operate the unit for at least 20 minutes.

2. Enter the Service mode. (See page 5-1)

3. Receive the monoscope pattern.

4. Press "9" button on the service remote control unit

and select "V-S" mode. (Display changes "V-S" and
"V-P" cyclically when "9" button is pressed).

5. Press "CH o/p" buttons on the service remote

control unit so that the monoscope pattern will be
90±5% of display size and the circle is round.

6. Turn the power off and on again. (Main power but-

ton on the TV unit.)

10. V. Position Adjustment

Purpose: To obtain correct vertical width of screen
image.

Symptom of misadjustment: If V. Position is incor-
rect, vertical height of image on the screen may not be
properly displayed.

Note: Use service remote control unit

1. Operate the unit for at least 20 minutes.

2. Enter the Service Mode. (See page 5-1)

3. Receive the monoscope pattern.

4. Press "9" button on the service remote control unit

and select "V-P" mode. (Display change "V-S" and
"V-P" cyclically when "9" button is pressed).

5. Press "CH o/p" buttons on the service remote

control unit so that the top and bottom of the mono-
scope pattern will be equal of each other.

6. Turn the power off and on again. (Main power but-

ton on the TV unit.)

11. U-Pedestal Adjustment

1. In VIDEO mode of V1, V2, or YUV, press "3" button

on the service remote control unit and select "U-
PED" mode. (Display changes "U-PED" and "V-
PED" cyclically when "3" button is pressed).

2. Switch the VIDEO mode to YUV. (Refer to “2. Initial

Setting.”)

3. To select one appropriate value in "0" to "15,"

press "CH o / p" buttons on the remote control
unit.

4. Switch the VIDEO mode to previous mode.

5. Turn the power off and on again. (Main power but-

ton on the TV unit.)

Test Point

Adj. Point

Mode

Input

---

CH o / p

buttons

RF

Mono-

scope

Tape

M. EQ.

Spec.

---

Monoscope

90±5%

Test Point

Adj. Point

Mode

Input

---

CH o / p

buttons

RF

Mono-

scope

Tape

M. EQ.

Spec.

---

Monoscope

90±5%

Test Point

Adj. Point

Mode

Input

---

CH o / p

buttons

RF

Mono-

scope

Tape

M. EQ.

Spec.

---

Monoscope

See below.