3100 Wood Stove Series (ACC)

R

D. Chimney Termination Requirements

Follow manufacturers instructions for clearance, securing,

fl ashing and terminating the chimney.

Must have an approved and listed cap

Must not be located where it will become plugged by
snow or other material

• Must terminate at least 3 feet (91cm) above the roof

and at least 2 feet (61cm) above any portion of the
roof within 10 feet (305cm).

• Must be located away from trees or other struc-

tures

These are safety requirements and are not meant to assure proper fl ue draft.

Figure 19.1

E. 2-10-3 Rule

Figure 19.2

NOTE:

• Chimney performance may vary.

• Trees, buildings, roof lines and wind conditions affect

performance.

• Chimney height may need adjustment if smoking or

overdraft occurs.

3 ft. (91cm)

Minimum

Less than 10 ft. (305cm)

2 ft. (61cm)

3 ft. (91cm)

Minimum

10 ft. (305cm) To Nearest Roofline

2 ft. (61cm)

Pitched Roof

10 ft. (305cm) or more

3 ft. (91cm) Minimum

Less than 10 ft. (305cm)

2 ft. (61cm)Minimum

3 ft. (91cm) Minimum

Wall or Parapet

Flat Roof