882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

Note: The prompt asks you if the video appearing on the connected display looks
good. “Looks good” means that there is a picture and an absence of excessive snow.

17. (Optional) To run a specific test you can use the command line as shown below:

CPTX:CPTR 25

// Selects specific test (e.g. 3B_01) see table below

CPTX:CPTU

// Initiates the execution of the test

You can query the complete list of tests to choose from:

CPTX:GCTN?

// Queries the list of tests supported

You can query the currently selected test to run with:

CPTX:CPTR?

// Queries the selected test to run (see table)

The following table describes the tests that can be performed.

To run the 3C-I series HDCP compliance tests on an HDMI repeater:

The 3C-I-01 test is run for each of the two read configurations: 1) short read and 2)
combined read. These multiple iterations are handled in the batch mode but you can
choose to run them through the command line as well.

CPTX:CPTR

I

ndex

Test

Description

25

3B_01 (Repeater Downstream
w/Repeater)

Regular Procedure: With Repeater

26

3B_02 (Repeater Downstream
w/Repeater)

Irregular Procedure: (Second Part of
Authentication) Timeout of KSV List READY

27

3B_03 (Repeater Downstream
w/Repeater)

Irregular Procedure: (Second Part of
Authentication) Verify V’

28

3B_04 (Repeater Downstream
w/Repeater)

Irregular Procedure: (Second Part of
Authentication) MAX_DEVS_EXCEEDED

29

3B_05 (Repeater Downstream
w/Repeater)

Irregular Procedure: (Second Part of
Authentication) MAX_CASCADE_EXCEEDED

Does the video look
good?

!Yes No!

Advertising