882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

14. Select

!CompRpt to initiate the HDCP compliance test.

The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.

Alternatively, you can run the tests using the following command:

CPTX:CPTR 46

// specifies that all applicable tests will be run.

CPTX:CPTU

// Initiates the execution of the test

Refer to

To view the HDCP compliance report:

” on page 42 for procedures on how to

view the generated report.

15. (Optional) To run a specific test you can use the command line as shown below:

CPTX:CPTR 30

// Selects specific test (e.g. 3C1_01) see

table below

CPTX:CPTU

// Initiates the execution of the test

You can query the complete list of tests to choose from:

CPTX:GCTN?

// Queries the list of tests supported

You can query the currently selected test to run with:

CPTX:CPTR?

// Queries the selected test to run (see table)

The following table describes the tests that can be performed.

CPTX:CPTR

I

ndex

Test

Description

30

3C_I_01 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)

Regular Procedure: Transmitter – DUT –
Receiver

31

3C_I_02 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)

Regular Procedure: HPD Pulse Output Caused
By User Operation

32

3C_I_03 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)

Irregular Procedure: (First Part of
Authentication) New Authentication

33

3C_I_04 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)

Irregular Procedure: (Second Part of
Authentication) New Authentication

34

3C_I_05 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)

Irregular Procedure: (Third Part of
Authentication) New Authentication

Advertising