Deployment & Installation

Cat-5 Cabling Considerations

Trango Broadband Wireless — Atlas5010

page 30

Cat-5 Cabling Considerations

Shielded twisted pair Cat-5 cable is recommended for all installations. The shield within the Cat-5 cable does not need to be
grounded if the radio itself is grounded. It is important to consider that most Cat-5 cable will deteriorate over time if exposed
to the weather (especially direct sunlight). It is recommended that installers place all Cat-5 cables inside conduit. Plastic
conduit is sufficient. If metal conduit is used, it is not necessary to use shielded Cat-5 cable.

Weatherizing

!


!

Important! Please note that the silicon strain relief has a small gap when the cable is
installed. This is normal .


It is important to provide strain relief and drip loop for STP Cat-5 cables. Do not mount the
radio upside down as water will enter the bottom of the radio and cause permanent damage

!

Important! The Power-over-Ethernet injector is not a weatherized device and must be
located either indoors or in a weather-protected cabinet.