User's Guide LDK 4502 - HDTV Camera Base Station

Installation

MCP Available

When no MCP is available it might occur that some
functions are in an undesirable position, for example, a lock
on the upper part of the OCP. To prevent this happening,
set the Base Station menu item

System \ MCP Available to

No when an MCP is not available.

The functions affected by this setting and their state are as
follows (if the item value is set to MCP Available = No):

Variable black stretch (Yes/No)

Yes

Variable gamma (Yes/No)

Yes

Variable Flare (Yes/No)

Yes

Saturation (Yes/No)

Yes

White clipper (Yes/No)

Yes

Knee slope (Yes/No)

Yes

Knee point (Yes/No)

Yes

Iris(Normal/Reverse)

Normal

OCP lock (Upper/Total)

Total

Intercom (System/Isolate)

System

Audio (External/MCP)

External

Aspect Ratio (External/MCP)

External

Aspect Ratio (4:3/16:9)

4:3

Autolight (Yes/No)

Yes