5-2

User's Guide LDK 4502 - HDTV Camera Base Station

Diagnostics

Diagnostic LED Indications

Camera Base Station

Camera

Communication

On Air

Base

Station

Camera

Connected

Test

Camera Communication

This green LED lights when the communications between
Camera and Base Station are OK.

Power Switch and indicator

Switches the power supply to the Base Station on and
off. A built-in light lights to indicate that power is being
supplied to the Base Station.

Base Station

This green LED lights when the local power supplies to
the Base Station are present.

LED Test

When the power to the Base Station is switched on
camera communication and on-air LEDs light
sequentially. If a LED does not light during start-up that
LED is probally defective.

Camera indicator - Test

This bicolour TEST LED lights red or yellow to indicate
the Camera and Triax status:
-

Red lights continuously – Triax short circuit.

-

Red flashes – Triax open circuit.

-

Yellow – Camera power switched off with the
Operational or Master Control Panel.

Camera indicator - Conected

This green CONNECTED LED lights when the Camera
is connected and the Camera power is not switched off
by the MCP, OCP or Base Station menu.

Diagnostic indicators for camera power

Communication

Test

Connected

off

off

green

Camera power switched off by the camera power switch.

off

yellow

off

Camera power switched off by the MCP, OCP or base station menu.