Wiring diagram fault finding, Preliminary electrical systems check – Tricity Bendix TBG 750 User Manual

Page 13

Advertising
background image

13

A. IGNITOR SWITCH

B. IGNITOR UNIT

B

L

N

0

1

2

3

4

5

6

220/240

A

Wiring Diagram

Fault Finding

Preliminary Electrical Systems

Check

A. EARTH CONTINUITY CHECK - Appliance must be

electrically disconnected - meter set on W (Ohms) x

1 scale and adjust zero if necessary.

a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1

ý (Ohm), check all earth wires for continuity and

all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically

disconnected, all switches ON.

a) meter set on W(Ohms) x 1 scale.

Test leads from L to N in appliance terminal block.

If meter reads «0» then there is a short circuit.

b) meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads

less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed

but no fault is indicated - a detailed continuity check

(i.e. by disconnecting and checking each

component) is required to trace the faulty component.

It is possible that a fault could occur as a result of

local burning/arcing but no fault could be found under

test. However a detailed visual inspection should

reveal evidence of burning around the fault.

START

Isolate appliance

and carry out:

A: Earth Continuity

check.

Has inlet fuse blown?

Carry out:

C: Polarity check.

Electricity supply

should now be

satisfactory.

Carry out:

D: Resistance to

Earth check.

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and

carry out:

B: Insulation check.

Rectify any fault

including replacing

fuses as necessary.

SOCKET

(face view)

PLUG (with cover

removed)

Earth Wire

Green/Yellow

Neutral Wire

Blue

Brown Blue

Green

Yellow

Green

Yellow

Brown

Blue

( )

FUSE

( )

E

N

L

NO

YES

NO

YES