Instructions for the installer, Engineers technical data – Tricity Bendix TBG 750 User Manual

Page 9

Advertising
background image

9

BURNER

RAPID

SEMI-RAPID AUXILIARY ULTRA-RAPID

(large)

(medium) (small) (double-crown)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL

POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

3.5

1.2

NOMINAL FLOW

RATE m

3

/h 0.286

0.062

0.190

0.043

0.095

0.031

0.333 0.114

NOZZLE REFERENCE

119

Adjust.

9 6

Adjust.

7 0

Adjust.

136 Adjust.

NOMINAL THERMAL

POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

3.5

1.2

NOMINAL FLOW

RATE g/h

202

4 7

144

3 2

7 2

2 4

252

8 6

NOZZLE REFERENCE

8 6

4 0

7 1

3 2

5 0

2 8

9 3

5 6

OVERALL DIMENSIONS

Width:

680 mm.

Depth:

510 mm.

Height:

72 mm.

CUT OUT DIMENSIONS

Width:

560 mm.

Depth:

480 mm.

Thickness: 30 mm.

Ignition HT Spark
Spark Generator

Ispra Control's BF 50066 - 240V 0.6 YA T 120

Spark Gap

Fixed

Rear Left Burner (semi-rapid)

Heat Input 2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

Heat Input 1.0 kW (3412 BTU/HR)

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid32
Rapid40
Ultra-rapid56
Aeration adjustment none

NATURAL

GAS

20

mbar

TYPE

OF

GAS

Characteristics

LPG GAS

28-30/37

mbar

1/100 mm

1/100 mm

VALUE

=

49.92

MJ/Kg

VALUE

=

37.78

MJ/m

3

Ws

- 50.7

MJ/

m

3

Rear Right Burner (semi-rapid)

Heat Input 2.0 kW (6824 BTU/HR)

Front Right Burner (rapid)

Heat Input 3.0 kW (10236 BTU/HR)

SUPPLY CONNECTIONS
Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non

rewireable plug fitted with a 3 amp cartridge fuse.

Central Burner (Ultra-rapid Double-crown)

Heat Input 3.5 kW (11942 BTU/HR)

Instructions for the Installer

Engineers technical data

APPLIANCE CLASS : 3

APPLIANCE

CATEGORY: II2H3+

APPLIANCE

GAS SUPPLY: Natural gas G20 / 20mbar

Advertising