119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08
50 2"
2000 78
3 4
"
2280 89
3 4
"
724 28
1 2
"
2550 100
3 8
"
D
Optimal height / suspended ceiling
Picture center
20
3 4
"
69 2
3 4
"
DETAIL D SCALE 1 : 5
Removable baseboard for access to outlets. Mounted with magnets.
Power / LAN outlets
Hardwire outlet for LED lights
LED mounted on bracket
T3 Lighting
04.11.08
01
119089
17.11.08
02
01.12.08
03
Doc. Title:
Sign.:
Date:
Revision:
Related Tandberg Product -
TANDBERG T3
Drw. No.:
Unit: mm / "