Troubleshooting, Lithium battery installation (optional), Problem probable cause remedy – Toro Plus Series Satellite User Manual

Page 16

Advertising
background image

Troubleshooting

If you experience a controller problem, check the programming for a possible programming error and the
list of problems and solutions listed below. If the problem continues, contact your local Toro distributor
for assistance.

Lithium Battery installation (optional)

An optional 3.9V lithium battery (P/N 363-2200) can be installed to sustain the controllers clock time and the
currently active program information for approximately 90 days with no additional power applied.

Procedure

1. Turn off power to controller at power supply switch.

2. Remove phillips screws from corners of control panel and

carefully lift panel up.

3. Turn control panel over, resting it face down on pedestal.

Connector cables can remain attached to PCB for this
procedure.

4. Remove five phillips screws from back of control panel

PCB and separate PCB from faceplate assembly.

5. Locate battery pin sockets located on front side of PCB

as shown at right. Insert battery carefully to avoid bending
contact pins. The pins are unevenly spaced allowing the
battery to be installed easily in one direction only. Do not
force battery pins into sockets
. See Warning above.

6. Reassemble control panel assembly and reinstall into

pedestal.

7. Restore power to controller at power supply switch.

16

WARNING

TO AVOID ELECTRICAL SHOCK HAZARD, ASSURE POWER SOURCE IS OFF BEFORE
ATTEMPTING ANY CONTROLLER REPAIR. ALL REPAIRS SHOULD BE PERFORMED BY A
QUALIFIED TECHNICIAN.

Problem

Probable Cause

Remedy

Controller inactive — no display

Controller on — valve(s) not
operating

Pump does not operate

Limited number of programs can
be operated at a time

a.m. or p.m. designation does not
appear with clock time

1. 4A control circuit breaker tripped.

2. Power supply On/Off switch in

Off (O) position.

1. Improper valve connection(s).
2. Station output module switch in Off

position.

3. 3.2A fuse blown.

1. Pump output module control switch

in Off position.

2. Pump component malfunction.

3. Improper pump connection(s).

1. DIP switch #1 and #2 position.

1. DIP switch #3 in Off position —

time displayed in 24-hour format.

1. Check output module switches. Set

ALL switches to Auto or Off. Reset
4A circuit breaker.

2. Position switch in On (–) position.

1. Check connections.
2. Set output module switch to Auto

position.

3. Replace 3.2A fuse

1. Set control switch to Auto position

2. Repair or replace faulty pump

components.

3. Check connections.

1. Check position of DIP switch #1 &

#2. See page 3.

1. Set DIP switch #3 to On position.

See page 3.

WARNING

DANGER OF EXPLOSION IF BATTERY IS INSTALLED INCORRECTLY. REPLACE ONLY WITH
THE SAME OR EQUIVALENT TYPE OF BATTERY. ALWAYS DISPOSE OF USED BATTERIES
ACCORDING TO THE BATTERY MANUFACTURER’S INSTRUCTIONS.

Advertising