10.1 Troubleshooting Guide

Troubleshooting

This chapter discusses ways to troubleshoot the TVP5154EVM.

If you are experiencing problems with the TVP5154EVM hardware or the WinVCC software, see

Table 21

for available solutions.

Table 21. TVP5154EVM Troubleshooting

SYMPTOM

CAUSE

SOLUTION

At startup, the error message Cannot find

The parallel port driver supplied with the

Run Port95NT.EXE on the CD to install

DLL file DLPORTIO.DLL appears.

EVM has not been installed.

the driver.

Go to Edit

Property Sheets

TVP5154,

Analog Video page, select the correct

Wrong video input is selected.

video input(s) and click Apply.
(The composite video input 1 is selected
by default.)

Blank screen

Source is connected to the wrong input

Connect source to the correct input

connector.

connector.

Go to Edit

Property Sheets

TVP5154,

Output Control page, check the enable

YCbCr outputs or clock output is disabled.

YCbCr outputs and enable clock outputs
check boxes and click Apply.

Go to Edit

Property Sheets

TVP5154,

Wrong mode is selected for color

Synchronization page, set the Fsc control

subcarrier genlock output.

format to RTC and click Apply.

No color

Go to Edit

Property Sheets

TVP5154,

GLCO pin is not set to output the GLCO

Output Control page, set the drop down

signal.

box labeled FID/GLCO (pin 23) to genlock
output (GLCO) and click Apply.

Go to Edit

Property Sheets

TVP5154,

Output Control page, set the YCbCr

Screen colors are only magenta and

Wrong YCbCr output format

output format to 8-bit 4:2:2 YCbCr

green.

w/ITU-R BT.656 embedded sync mode
and click Apply.

Go to Edit

Property Sheets

TVP5154,

Mode Selection page, uncheck all

Auto-switch masks are not set correctly.

standards to be included in auto-switch

Video standard auto-switch does not work

processing and click Apply.

on the video decoder side.

Go to Edit

Property Sheets

TVP5154,

Video decoder is not in auto-switch mode.

Mode Selection page, set the drop-down
box to multistandard and click Apply.

Click real-time polling in the Tools menu.

Video standard auto-switch does not work

Auto-switch polling is not enabled.

Click Enable All and OK. This should be

on the video encoder side.

disabled if using a composite output.