ELECTRONIC CONTROLLER INSTRUCTION

5-2. FUNCTION TABLE

No

Control Function Control Objects

Contents

Remark

1

Initial

Buzzer

Operation

Fan
Lamp
88 LED

2

Temperature

Compressor

Control

Evap-Fan Motor
Con-Fan Motor
LED

3

Turbo

Compressor

Freeze

Evap-Fan Motor
Con-Fan Motor
LED

1. Buzzer will be ring within 2 seconds when you plugged-in and turned

on the power switch.

2. 88 LED displays inside temperature.
3. Compressor will be run if evaporator's temperature is higher than

38.3˚F(3.5˚C), compressor will not run for 3 minutes when you
plugged-in.

4. The fluorescent lamp will come on, when the inside temperature has

reached 23˚F(-5˚C).

5. If inside temperature is lower than -50˚F or higher than 50, 88 LED

displays 'Lo' or 'Hi' respectively.

6. Evap. Fan Motor will be run if D-sensor sense lower than 14˚F or 10

minutes has passed from when you plugged-in.

1. By pushing up/down button, you can set the desired inside

temperature from '5˚F' to '-17˚F'.

2. 88 LED will display a setting temperature, when you push up/down

button.

3. 88 LED will indicate real inside temperature, after your setting.
4. Buzzer rings 1 time whenever each button is pressed.
5. Compressor automatically turns on and off by F-sensor (Except

error mode)

6. Compressor will not come on for 3 minutes After Compressor is Off,

even though the F-sensor is at On point.

7. Evap. Fan Motor runs continuously except when door is opened and

during defrost mode.

8. Evap. Fan Motor will start within 3 seconds when door is closed.
9. Compressor On/off temperature(˚F)

1. If the Turbo Freeze button is pressed, the Turbo freeze mode will

start.

2. If the Turbo Freeze button is pressed during the Turbo Freeze mode,

the Turbo Freeze mode is cancelled.

3. During the Turbo Freeze mode, the temperature up/down button will

not by operated.

4. T.F lamp in 88 LED is lighted during the Turbo Freeze mode.
5. The compressor and Condenser-Fan Motor operate continuously for

120 minutes.

Setting

Comp On

Comp Off

Setting

Comp On

Comp Off

Setting

Comp On

Comp Off

Setting

Comp On

Comp Off

Setting

Comp On

Comp Off

5

9

1

0

4

-4

-5

-1

-9

-10

-6

-14

-15

-11

-19

4

8

0

-1

3

-5

-6

-2

-10

-11

-7

-15

-16

-12

-20

3

7

-1

-2

2

-6

-7

-3

-11

-12

-8

-16

-17

-13

-21

2

6

-2

-3

1

-7

-8

-4

-12

-13

-9

-17

1

5

-3

-4

0

-8

-9

-5

-13

-14

-10

-18