Electronic controller instruction – Turbo Air TGM-14RV User Manual

Page 106

Advertising
background image

103

ELECTRONIC CONTROLLER INSTRUCTION

No

Control Function Control Objects

Contents

Remark

5

Defrost

Heater

Function

Compressor
Evap-Fan Motor
Con-Fan Motor

6

Manual

Compressor

Defrost

Evap-Fan Motor
Con-Fan Motor
Heater

7

Comp

Compressor

Restart

Con-Fan Motor

Prevent

8

Power

Compressor

Failure

Evap-Fan Motor

Back-Up

Con-Fan Motor

Function

9

Door opening

Buzzer

Alarm function

LED

10

Buzzer

Buzzer

Function

11

Error

LED

Display

f. If Defrost Heater's on time exceeds 40 minutes for any reason, a

back-up defrost termination switch is also provided.

g. If D-sensor's temperature does not reach 47˚F(8˚C) in 40 minutes,

error code will be recorded on a MICOM.

C. Pause step

a. Time = 3 min.
b. 88 LED displays 'dF'

D. Fan delay step

a. Max. Time = 5 min
b. Only Comp. is On.
c. If D-sensor temperature goes down under 14˚F in 5 minutes,

Evap.-Fan Motor turns on immediately.

1. Press the Turbo Freeze button 5 seconds, While pressing both

up/down button at the same time.

2. Manual defrost mode.

a) The pre-cool step is omitted.
b) It starts from heater defrost step.
c) The next procedure is the same as that of the defrost mode.

1. Compressor will not start for 3 minutes after compressor is off, even

though the F-sensor is at on point.

1. Compressor will not strat for 3 minutes after power failure.
2. Evap.-Fan Motor is on.

1. If door is opened, light on display board for fan turns off and door

open indicating lamp turns on.

2. If door is opened more than 30 seconds, display will beep 3 times.
3. If door is opened more than 60 seconds, display will beep 5 times.
4. If door is opened more than 5 minutes, display will beep

continuously.

1. Beep sound rings 1 time after initial power on.
2. Beep sound rings whenever each button is pressed.
3. Beep sound rings if door is opened a certain time period. (See door

opening alarm function)

1. Press up button 5 times while pressing both down button and Turbo

Freeze button at same.

Above procedure switches normal display to error display mode.

2. If there was no error occurred, there will be no change on the 88

LED.

If there was error occurred, 88 LED will display the error code.

3. Next error code will be displayed by pressing down button.
4. 10 seconds after the last button pressed, error display mode will be

switched to normal display mode.

TEMPERATURE