TOA Electronics DIRECT VENT 600 User Manual

Page 27

Advertising
background image

27

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

SIT Millivolt Gas Valve

Pilot for SIT Millivolt Gas Valve

Pressure
Regulator

Remove
These
Components

Orifice Strip Tab

Pilot Hood Position After
Loosening Hex Fitting 1/4 Turn

Push Tab to Set

Gas Type Usage

Note - Orifice Strip Tab May
Be Randomly Located On Any
Side Of The Hex Fitting

Hood Alignment

Hood

7/16 in. Open End Wrench

Orifice Strip Tab

Take Care Not to Contact the Orifice Strip Tab

with the Hex Fitting Wrench - Distortion of the Tab

May Render the Pilot Inoperative.

Figure 63

Figure 62

Pilot
Orifice

b. Attach manometer to the manifold side
pressure test fitting and verify manifold pres-
sure reads 3.5 inches water column (0.87 kPa)
for natural gas, and 10.0 inches water column
(2.49 kPa) for propane gas.

Step 4. Millivolt Appliances - SIT Systems

a. Refer to

Figure 62 and the instructions

provided with the kit. Using a Torx T20, remove
and discard the three pressure regulator mount-
ing screws. Remove the pressure regulator,
spring, poppet, diaphragm and bushing. Dis-
card all removed components
. Ensure the
rubber gasket installed on the back of the
replacement pressure regulator is properly
positioned and install the new pressure regula-
tor using the new screws supplied with the kit.
Tighten screws to 25 In. lb. torque.

Step 1. Turn off the gas supply to the appliance.
Remove the front glass door/frame from the
appliance. Access the control compartment.

Step 2. Carefully remove the logs. Exercise
care so as not to break the logs.

Pilot for Honeywell Millivolt Gas Valve

(Loosening of Hex Fitting For Orifice Strip Tab Positioning)

Pilot for Honeywell Millivolt Gas Valve

Figure 66

Step 3. Locate the screws securing the burner
(tray) to the appliance. Remove the burner and
retain the securing screws.

Pilot for Honeywell Millivolt Gas Valve Orifice Strip Tab Positioning

Figure 64

Figure 65

Natural Gas Position -

NAT shown on tab

LP/Propane Gas Position -

1/16 in. Hole, LP and

Red Color shown on tab

NAT

P

L

Orifice Strip Tab Position Identification

For LP/Propane and Natural Gas

Top View of Hex Fitting and Orifice Strip Tab

c. Refer to

Figure 63 and remove the pilot

hood assembly to access the hexed pilot ori-
fice. Remove and replace the orifice with the
one provided with the kit.

Advertising