Fireplace framing specifications – TOA Electronics DIRECT VENT 600 User Manual

Page 7

Advertising
background image

7

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

l

e

d

o

M

.

o

N

A

B

C

D

E

F

0

0

5

-

D

0

0

5

-

T

D

0

0

5

-

R

D

.

n

i

8

/

1

5

3

2

/

1

7

5

8

/

5

0

4

6

1

/

3

9

1

4

/

3

8

2

8

/

1

6

m

m

2

9

8

1

6

4

1

2

3

0

1

7

8

4

0

3

7

6

5

1

0

0

6

-

D

0

0

6

-

T

D

0

0

6

-

R

D

.

n

i

8

/

1

0

4

6

1

/

3

1

6

2

3

/

1

3

4

6

1

/

3

9

1

6

1

/

1

1

0

3

8

/

7

7

m

m

9

1

0

1

4

5

5

1

1

0

1

1

7

8

4

9

7

7

0

0

2

0

0

8

-

D

0

0

8

-

T

D

0

0

8

-

R

D

.

n

i

8

/

1

5

4

8

/

3

6

6

6

1

/

5

1

6

4

6

1

/

3

9

1

6

1

/

3

3

3

4

/

3

9

m

m

6

4

1

1

6

8

6

1

2

9

1

1

7

8

4

3

4

8

8

4

2

C

Back wall of chase/enclosure

(including any finishing materials)

a

7 (178)

b

Note-
Venting requirements for rear vent applications in corner
installations -
- the the round termination (SV4.5HTR) may not be used
- the horizontal vent length “a” to “b,” must not exceed 28
inches (711 mm)

Inches

(millimeters)

*These dimensions occur when one 45

degree elbow is connected directly to the

appliance collar.

D and DR units

D and DT units

*D

E

*F

A

B

.

o

N

l

e

d

o

M

A

B

C

D

0

0

5

-

D

.

n

i

4

/

1

5

3

4

/

1

5

3

6

1

/

1

1

1

2

8

/

1

9

3

m

m

5

9

8

5

9

8

1

5

5

4

9

9

0

0

5

-

T

D

.

n

i

4

/

1

5

3

4

/

1

5

3

-

-

-

-

8

/

1

9

3

m

m

5

9

8

5

9

8

-

-

-

-

4

9

9

0

0

5

-

R

D

.

n

i

4

/

1

5

3

4

/

1

5

3

6

1

/

1

1

1

2

-

-

-

-

m

m

5

9

8

5

9

8

1

5

5

-

-

-

-

0

0

6

-

D

.

n

i

4

/

1

0

4

4

/

1

0

4

6

1

/

1

1

6

2

8

/

1

4

4

m

m

2

2

0

1

2

2

0

1

8

7

6

1

2

1

1

0

0

6

-

T

D

.

n

i

4

/

1

0

4

4

/

1

0

4

-

-

-

-

8

/

1

4

4

m

m

2

2

0

1

2

2

0

1

-

-

-

-

1

2

1

1

0

0

6

-

R

D

.

n

i

4

/

1

0

4

4

/

1

0

4

6

1

/

1

1

6

2

-

-

-

-

m

m

2

2

0

1

2

2

0

1

8

7

6

-

-

-

-

0

0

8

-

D

.

n

i

4

/

1

5

4

4

/

1

0

4

6

1

/

1

1

6

2

8

/

1

4

4

m

m

9

4

1

1

2

2

0

1

8

7

6

1

2

1

1

0

0

8

-

T

D

.

n

i

4

/

1

5

4

4

/

1

0

4

-

-

-

-

8

/

1

4

4

m

m

9

4

1

1

2

2

0

1

-

-

-

-

1

2

1

1

0

0

8

-

R

D

.

n

i

4

/

1

5

4

4

/

1

0

4

6

1

/

1

1

6

2

-

-

-

-

m

m

9

4

1

1

2

2

0

1

8

7

6

-

-

-

-

A

B

D

7

(178)

5

¹⁄₈

12

¹⁄₈

(308)

10

¹⁄₂

(

267

)

C

VENT FRAMING -

TOP VENT WITH ONE

90

°

ELBOW

VENT FRAMING -

REAR VENT WITH

NO ELBOWS

Framing should be constructed

of 2x4 or larger lumber.

Inches (mm)

(130)

5

¹⁄₈

(130)

7

(178)

16” (406mm) is the required framing depth dimension when

the finish material (drywall) thickness is 1/2 in. (13mm).

¹⁄₂ A

**FRAMING WITH SQUARE HORIZONTAL TERMINATIONS (SV4.5HTSS or SV4.5HTS)

AND ROUND HORIZONTAL TERMINATION (SV4.5HTR)

** See the horizontal venting Figures 33 and 34 on page 16 for restrictions on the use of the

round termination (SV4.5HTR).

12

¹⁄₈

(308)

16

(406)

Figure 9

Figure 10 Corner Framing with Square Termination (SV4.5HTS)

Framing Dimensions

FIREPLACE FRAMING SPECIFICATIONS

Advertising