CODE

SYMPTOM

PROBABLE CAUSE

SOLUTION

DSO

Open-Circuit in evaporator
temperature sensor

Heat pump stopped

The evaporator temperature sensor
is incorrectly plugged in or defective

Reset the heat pump from the
breaker

Call an authorized technician

SO

Open-Circuit in water
temperature sensor

Heat pump stopped

The water temperature sensor is
incorrectly plugged or defective

Reset the heat pump from the
breaker

Call an authorized technician

DSc

Short circuit in evaporator
temperature sensor

Heat pump stopped

The evaporator temperature sensor
is incorrectly plugged in or defective

Reset the heat pump from the
breaker

Call an authorized technician

Sc

Short circuit in water
temperature sensor

Heat pump stopped

The water temperature sensor is
incorrectly plugged or defective

Reset the heat pump from the
breaker

Call an authorized technician

LP

Low pressure detected in
circuits

Heat pump stopped

Loss of refrigerant

Defective captor or cable

Defective fan

Dirty evaporator

Defrosting captor is defective

Reset the heat pump from the
breaker

Call an authorized technician

Call an authorized technician

Call an authorized technician

Clean the evaporator

Call an authorized technician

HP

High pressure detected in
circuits

Working resumption when
the pressure becomes
normal again

Water flow either slow or blocked
by an obstruction

Defective captor or cable

Reset the heat pump from the
breaker

Adjust the water flow

Call an authorized technician

HP4

4 high pressures detected
in circuits

Heat pump stopped

Water flow either slow or blocked
by an obstruction

Defective captor

Adjust the water flow
Clean pool filter
Reset the heat pump from the
breaker

Call an authorized technician

ERROR CODE LIST