Taylor Pool Heat Pump User Manual

Page 23

Advertising
background image

C OD E

S YMPTOM

PR OB AB LE C AU SE

S OLU TION

PE

Los s of m em ory in the control

Res um ption of default param eters

Pow er failure

Pow er output variation. The c ontrol
accepts a voltage range betw een 20VAC
and 30VAC

R eset the heat pum p from
the breaker. The control is
back to factory settings ,
c all an authoriz ed
technician to recover
pers onalized settings (not
c overed by warranty)

C all an authoriz ed
technician if there are still
problem s

C O

Error of com m unication
betw een the c ontrol and the rem ote control

C ables are inc orrectly plugged in or
defective
D efective c ontrol or rem ote c ontrol

R eset the heat pum p from
the breaker.

C hec k c onnections .

C all an authoriz ed
technician

D F

For the hot-gas defrosting option. The
defrosting operation has not finis hed in the
predefined tim e.

Heat pum p stopped. Unplug the heat pum p
and then plug it back in to res tart the control.
If the problem persists, c ons ider the
following options.

R eversing valve blocked

D efrosting captor is defec tive

C om pressor is inactive in defros ting
m ode

R eset the heat pum p from
the breaker.

C all an authoriz ed
technician

FF

No water flow when pum p operated by the
control (sw im m ing pool pum p control option
only)

Res um ption of ac tivities if water flow is
detected

The valves of the heat pum p are clos ed

The pum p is disconnected

The pipes are obs truc ted

The water flow detector is defective: the
w ater circulates in the heat pum p but is
not detected

R eset the heat pum p from
the breaker.

O pen the valves of the
heat pum p

C onnec t back the heat
pum p

Unblock the pipes

C all an authoriz ed
technician

C F

Configuration of invalid option

R eset the heat pum p from
the breaker.

PF

Los s of power

Dis appear 10 sec .

Heat pum p was disconnected
There w as a power failure

R eset the heat pum p from
the breaker.

W ait

23