Wireless remote controller kit

Installation Manual

– 3 –

2

SWITCH LOCATION OF SIGNAL RECEIVING

UNIT

1

3

2

4

6

5

Screw

Remove

Face plate

Remove the face plate from Signal receiving unit.

Signal receiving unit

Address selector switch
This switch is used to address one of a
maximum of six air conditioners that can
be controlled by the remote controller.
(Refer to page 11.)

All

x

{

/NORMAL selector switch

Set this switch to the “NORMAL” position for the normal operation of the air conditioner. When this switch is set to the
“All

x

{

” position, the indoor unit of the air conditioner is turned off.

RCU:SUB/RCU:MAIN selector switch
Set this switch to the “RCU:MAIN” position for normal operation. Refer to page 9 for setting to the “RCU:SUB” position.

PCB CHK switch
This switch is not used and should be set in the position shown in the figure.

TEST RUN switch
This switch is used for test running.