Table of Contents

Safety Precautions ....................................................................... 2
1. Intended Application ................................................................ 2
2. Specifications .......................................................................... 2
3. Installation ............................................................................... 3

3.1 Location ........................................................................... 3
3.2 Electrical Requirements .................................................... 3
3.3 Condensate Removal ........................................................ 3
3.4 Ducting ............................................................................. 3

3.4A Installing Duct Collars ................................................ 3
3.4B Ducting for Dehumidification ..................................... 3
3.4C Ducting for Fresh Air .................................................. 4
3.4D Installation in a basement ......................................... 4
3.4E Installation in a attic .................................................. 5
3.4F Installation with (2) HVAC systems ............................. 5
3.4G Installation without an HVAC system .......................... 5

3.5 Quiet Installation ............................................................... 5

4. Controls ................................................................................... 5

4.1 Humidity/Fan Control Panel ............................................... 5
4.2 Ventilation Timer & Humidity Control Panel ....................... 5
4.3 Humidity Control Adjustment ............................................ 6
4.4 Fan/Filter Switch ............................................................... 6
4.5 Ventilation Timer ............................................................... 6
4.6 High Efficiency Air Filter .................................................... 7
Control Package Diagram Sheet ............................................. 8

5. DEH 3000/DEH 3000R Digital Control ..................................... 9
6. Maintenance .......................................................................... 10

6.1 Standard Air Filter ........................................................... 10
6.2 High Efficiency Air Filter .................................................. 10

7. Service .................................................................................. 10

7.1 Warranty ........................................................................ 10
7.2 Technical description. ..................................................... 10
7.3 Troubleshooting ............................................................. 10
7.4 Refrigerant Charging ...................................................... 11
7.5 Fan Replacement ............................................................ 11
7.6 Compressor/Capacitor Replacement ............................... 11

7.6A Checking Compressor Motor Circuits ....................... 11
7.6B Replacing Burned Out Compressor .......................... 12
7.6C Replacing Compressor-Nonburn Out........................ 12

7.7 Remote Controls ............................................................. 12

7.7A Humidity Control ...................................................... 12
7.7B Ventilation Timer ...................................................... 13

7.8 Defrost Thermostat ......................................................... 13
7.9 Electric Ventilation Damper ............................................. 13

Electrical Schematic .................................................................. 14
Pictorial Electrical Diagram ........................................................ 15
Service Parts List ....................................................................... 16
Optional Parts List...................................................................... 17
External Insulation Kit ................................................................ 18
Control Panel Installation ........................................................... 19
Warranty .................................................................................... 20

Safety Precautions

Read the installation, operation and maintenance
instructions carefully before installing and operating this device. Proper
adherence to these instructions is essential to obtain maximum benefit
from your Ultra-Aire indoor air quality system.

Read and save these instructions

• The device is designed to be installed INDOORS IN A SPACE THAT IS

PROTECTED FROM RAIN AND FLOODING.

• Install the unit with space to access the front panel for maintenance

and service. DO NOT INSTALL UNIT WITH THE FRONT PANEL
INACCESSIBLE.

• Avoid directing the discharge air at people, or over the water in pool

areas.

• If used near a pool or spa; be certain there is NO chance the unit

could fall into the water, splashed and that it is plugged into a GFCI
GROUND FAULT CIRCUIT INTERRUPT OUTLET.

• DO NOT use the device as a bench or table.
• DO NOT place the device directly on structural members.
• A drain pan MUST be placed under the unit if installed above a living

area or above an area where water leakage could cause damage.

1.

Intended Application for Ultra-Aire 100V

For the ideal installation, draw air from the central part of the home
and return it to isolated areas of the home like the bedrooms, den,
utility room, or family room. The ductwork of the existing heating
system can be used to supply air to the home.

2. Specifications

Part Number:

4022200

Blower:

240 CFM @ 0.1" WG

Supply Voltage:

115 Volt – 1 Phase – 60 Hz.

Amps:

6.8

Energy Factor:

2.51

Operating Temp.:

56°F Min, 100°F Max

Sized For:

2500 Square Foot Typical

Minimum Performance at Set Conditions

Intake Air:

80°F, 60% RH

Capacity:

100 Pints/Day @ 80°F/60% RH

Pints/kWh:

5.3

UA-100V Duct Connections:

6" Round Inlet , 8" Round Inlet, 8" Round Outlet
Filter Efficiency:

Standard MERV-11 (65% ASHRAE Dust Spot)

Optional MERV-14 (95% ASHRAE Dust Spot)

Power Cord:

9', 115V With Ground

Drain Connection:

.56" ID x 8’ Vinyl Hose

UA-100V Dimensions:

Unit

Shipping

Width:

21" without collars, 24" with collars

30"

Height: 42" without collars, 48" with collars

47"

Depth:

17"

25"

Weight: 119 lbs

134 lbs