Network clocked t1 facilities, Connect t1 facilities – Texas Instruments 3000 MCU User Manual

Page 15

Advertising
background image

SpectraLink Corporation

T1 Remote Module Installation

Link WTS – Link 3000 MCU

Network Clocked T1 Facilities

If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as
the Master Clock Source. Connect the

Sync IN

port on this T1 Remote Module to

AUX

port

A

on the Intershelf Junction Panel. Note, this shelf must also be designated as the

Master Clock in the system configuration.

Connect T1 Facilities

Connect the RJ48C jack from the

CSU

port at the local end to the

DS1 A

and

DS1 B

ports on the T1 Remote Module. Port A controls slots 3-7 on the remote module at the
far end. Port B controls slots 8-12.
The following diagram shows the T1 Remote Module connections at the LOCAL site.

Part Number: 72-0059-06-E.doc

Page 15