Input Signal
Electronically balanced inputs for the connection of
high-level signal sources such as mixers, signal
processors, etc. Establishing the connection is
possible via phone or XLR-type jacks. Balanced
connection is recommended to prevent noise or
HF-interference.

Caution: Before connecting or disconnecting any
plugs, make sure to set the level control to its
counterclockwise stop, which prevents the system,
the audience and yourself from being stressed by
nasty contact noise.

Input Loop
Output is full bandwidth pass through.

Level
This control sets the output volume of the P1 or P2
in a range between -

dB and +6dB. The internal

power amplifier provides a nominal input sensitivity
of +6dBu.

Level adjustment knob shown in place. Unit is
shipped preset at 0 dB without knob installed
(knob is shipped separately with your Plasma
System). If knob is not used, please remember
where you store it. Customer can adjust level by
removing cover, pressing knob in place, and
rotating to desired level.

CAUTION: THIS APPLIANCE HAS
NO USER-SERVICABLE PARTS
INSIDE. LEAVE ANY SERVICING
AND MAINTENANCE QUALIFIED

SERVICE TECHNICIANS ONLY.

Crossover Mode Switch
Selects between 40 Hz highpass filter for
Fullrange use, and 100 Hz highpass filter for use
with Plasma P2 subwoofer. It is not recommended
that you use your P1 in Fullrange with subwoofers.