Tandberg Data FS-1610 User Manual

Page 14

Advertising
background image

Tandberg Data

Setting Up

_____________________________________________________________

2-2

Tandberg Viking FS-1600 Series NAS Hardware User Manual

.

2.1.3. Rack

Mounting

When mounting your FS-1600 Series NAS appliance into a cabinet
(equipment rack), make sure you maintain correct mechanical load leveling
to avoid hazardous conditions.

2.1.4. Power

Source

The FS-1600 Series NAS appliance should be operated using only the type
of power source indicated on the product label.

• Voltage: 100-240 V
• Current: 4-10 A
• Frequency: 50/60 Hz

2.1.5. Circuit

Overloading

Appropriate consideration should be given when connecting the supply
circuit to the FS-1600 Series NAS appliance to avoid any circuit overload.
The system nameplate rating should be used when addressing concerns
about circuit overload.

Warning

Make sure that the site has the necessary capacity to handle the FS-1600
Series NAS appliance. Overloading electrical supply circuits is extremely
hazardous.

2.1.6. Reliable

Grounding

To avoid the potential for an electrical shock hazard, the rack assembly itself
must be suitably grounded, according to your local regional electrical codes.
This typically will require the rack to have its own separate ground. We
recommend you consult your local approved electrician.

2.1.7. Electrical

Shock

Do not operate the FS-1600 Series NAS appliance without the top cover in
place. Opening or removing the cover may expose you to dangerous voltage
and can cause electrical shock.

2.1.8. Battery

Precaution

There may be a danger of explosion if the CMOS battery is incorrectly
replaced. Replace this battery with model CR2032 only. Use of another
battery may present a risk of fire or explosion. Dispose of used batteries
according to manufacturer's instructions.

Advertising
This manual is related to the following products: