Changeable Components and Test Points

Changeable Components and Test Points

C1, C2, C3, C4—input capacitors, at least 0.047

µ

F total on each input.

C5, C6, C8, C9—load capacitors, vary according to loads, but C5 plus C6 must
be at least 4.7

µ

F.

R2—top resistor of the resistor divider, refer to data sheet for its resistance
value.

R1—LDO_PG pullup resistor, must be at least 1k

.

A total of 16 test points are provided. Besides four black test points on the four
corners of the EVM, there are 12 more test points (11 red and 1 black) residing
on two sides of the white rectangle box at the center of the EVM. Their
respective testing signals are listed in the following table, when looking at the
EVM from top down. The test-point orders are listed from top to bottom on both
sides.

Table 3–1. Test Points and Test Signals

Left-side
Test-Point Order

Color

Signal

Right-side
Test-Point Order

Color

Signal

1

Red

SW_PG

1

Red

SW_PLDN

2

Red

SW_IN

2

Red

SW_OUT

3

Red

LDO_IN

3

Red

LDO_OUT

4

Red

SW_EN

4

Red

LDO_PLDN

5

Red

LDO_EN

5

Red

ADJ

6

Black

GND

6

Red

LDO_PG