the evaporator more quickly and efficiently. See Figure 3
below for correct grain control magnet position and defrost
timer for operating in temperatures below 50°F.

DRYING TIP: Air’s ability to absorb moisture from wet
surroundings and the Phoenix 200 HTs ability to remove
moisture from that air is greatly improved at higher
temperatures. The defrost cycle is automatic and designed
for optimum performance above 50°F. If the unit is used
in an area that is below 50°F for more than 2 hours,
adjustment of the defrost timer is recommended.

To adjust the defrost timer:
. Unplug the unit.
2. Remove the top panel and the front cover (6 screws).
3. The timer is fastened to the base at the front of the

unit. Every third peg around the dial is pushed out
from the dial center except one section with 4 pegs
out in a row. The grain control (8 holes at the intake
of the unit below the filter) should be open. Refer to
Figures 2 and 3.

4. To improve performance below 50°F, the compressor

“off” time must be increased to allow the frost to
completely melt. To do this, push the pegs out from
the dial center so that the pegs alternate with 2
toward the center, then 2 out from the center, all the
way around the dial except for the section now with 6
pegs out in a row. Refer to Figure 3.

5. Replace the cover and top panel.

2.9 Low Pressure Control

If the low side refrigerant pressure drops to 5 PSIG, the
low pressure control opens and shuts off the compressor
and blower. It is an automatically reset control. Its primary
function is to prevent damage to the compressor if a leak
develops in the refrigeration system. It may also open if
the unit is A) used in a cool area (below 50°F) and the
defrost timer is not adjusted or B) stored where it is below
40°F and then started. Under these conditions, the unit
will restart within several minutes; it may cycle several
times until the unit warms up.

3 Maintenance

3.1 Air Filter

The Phoenix 200 HT is equipped with a pleated fabric air
filter that must be checked regularly. The standard filter
is a MERV- high efficiency filter. Operating the unit with
a dirty filter will reduce the dehumidifier’s capacity and
efficiency and may cause the compressor to cycle off and
on unnecessarily on the defrost control.
The filter can generally be vacuumed clean several times
before needing replacement. Replacement filters can be
ordered from the factory or purchased locally if available.

WARNING: DO NOT operate the unit without the filter or
with a less effective filter as the heat exchange coils inside
the unit could become clogged and require disassembly to
clean.

3.2 Storage

There are two issues to consider when the Phoenix
200 HT is stored between uses and both pertain to the
water trapped in the unit: damage caused by freezing or
biological growth.
The effect of the trapped water can be greatly reduced
if precautions are taken to remove as much as possible
before storage.
. Use the pump purge switch to reduce the water level

in the reservoir.

2. Stretch the hose flat to drain it completely.
If the unit will not be exposed to freezing temperatures, an
alternative to reduce biological growth is to flush the unit
with a bio-fungicide that is approved for use with copper,
aluminum and polyethylene. To flush:
. Run the hose to a drain.
2. Remove the air filter. Slowly pour a quart of the

chemical through the top grille so that it drains into
the plastic slots.

4. Hold in the pump purge switch to reduce the water

level in the reservoir.

4 Service

WARNING: Servicing the Phoenix 200 HT with its high
pressure refrigerant system and high voltage circuitry
presents a health hazard which could result in death,
serious bodily injury, and/or property damage. Only
qualified service people should service this unit.
Do not operate unit without the front panel in place.

Figure 3: Defrost timer and grain control magnet position for
operating in temperatures below 50°F.