Toshiba TEC H-9000 User Manual

Page 28

Advertising
background image

9.

PROGRAMMING PROCEDURES

9.2 PLU DATA SETTING

9- 6

NOTES:

1. A UPC code is made up of a combination of an entered code and an AUTO CODE. Be

sure to attach some

characters to the end of the AUTO CODE, or all entered codes

will be ignored and an AUTO CODE will become an UPC code (see ex. 1).
ex. 1) enter code:

456

ex. 2) enter code:

4567

ex. 3) enter code:

123456

AUTO CODE: 123---

AUTO CODE: 123---

AUTO CODE: 987

code#: 123456

code#: 123567

code#: 987

2. When there is no area to store PLU data, an error occurs when pressing the

key.

3. Changing a PLU # to the number to which other PLU data is set will result in an error.
4. Unit price flag may be selected as follows:

a.

key : $ per lb

b.

key : $ per 1/2 lb

c.

key : $ per 1/4 lb

5. Tare limit should be a multiple of 5, up to 2.000 lb for US type.
6. Safe handling instructions can be printed on 57-mm wide labels only. Safe handling

instructions are printed on labels formatted for ingredient messages. Only ingredient
message labels with 13 or more lines can be used to print safe handling instructions.
Available print formats are as follows:
13 (63), 15 (65), 16 (66), 23 (73), 25 (75), 26 (76), 33 (83), 35 (85), 36 (86), 41, 42, 43, 48
and 49.

7. Tare % indicates a percentage of tare in gross weight, which is available when the initial

Setting #28-4 is set to 1.

8. When setting open prices in the count mode (Initial Setting #1-6: 1), set zeros as quantity

and unit price.

ENTER

INSERT 1

RETURN 1/4

DELETE (A) 1/2

Pressing the

key instead of the

key advances to the next menu. Pressing the

key returns to the preceding menu.

Verification label of PLU data

ENTER

(W: Weigh, F: Fix, B: By-count)

(C: Compulsory, Blank: Not

compulsory)

Advertising
This manual is related to the following products: