Optional matching transformer mounting, Caution – TOA Electronics 1000 Series User Manual

Page 9

Advertising
background image

Optional Matching Transformer Mounting

[CAUTION]

THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY.
TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN
THAT CONTAINED IN THE OPERATING INSTRUCTIONS

UNLESS YOU ARE

QUALIFIED TO DO SO. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL.

The E-1231's input and output are electronically balanced. These can be converted to
transformer balanced input and output using the optional matching transformer LT-101

(input) and LT-102 (output).

1. Set the power switch to OFF and unplug the AC cord form a wall outlet.

2. Remove the case by loosening six side panel screws (three each on each side)

and two rear panel screws.

3. Install sleeves (supplied with the transformer) by tightening screws from the other

side of a chassis, and mount the transformer to the sleeves using screws. See Fig.
1.The input transformer must be located on the left and the output transformer on

the right.

4. When mounting the input transformer, detach

connector from CN-104, reconnect

the detached connector to

connector at the transformer side, and then connect

connector from the transformer to CN104.
When mounting the output transformer, detach

connector from CN-103,

connector at the transformer side, and then

connector from the transformer to CN103.

reconnect the detached connector to

See Fig.1.

connect

Fig.1

5. Fit the case in place.

Transformer Specifications

Model

Frequency response

Constant loss

Distortion

LT-101

30Hz ~ 20kHz

(at ±0.15dB)

Within 1.5dB(at 1kHz)

Less than 0.2%(50Hz/5dB)

LT-102

30Hz ~ 20kHz

(at ±0.15dB)

Within 1.5dB(at 1kHz)

Less than 0.2%(50Hz/5dB)

0dB = 0.775V RMS

Specifications are subject to change without notice.

— 9 —

Advertising