Connecting the power

2.

d

WARNING

d

Electrical Shock Hazard

- Plug into a grounded 3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
Failure to follow these instructions can result in

death, fire, or electrical shock.

The appliance comes with a 3Ćwire power supply cord,

UL listed in the USA.
The appliance requires a 3Ćwire receptacle.
The receptacle must be installed by a licensed

electrician only.
Orient ground prong to the bottom as shown in the

pictures.
For the installation position of the receptacle see

"Installation dimensions", page 8.

Additional grounding procedure

3.

Some local regulations may require a seperate ground.

In such cases, the required accesseory ground wire,

clamp and screw must be purchased seperately.
Never ground the appliance to plastic plumbing lines,

gas lines or water pipes.

Grounding instruction

This appliance must be grounded. In the event of

a malfunction or breakdown, grounding will reduce

the risk of electric shock by providing a path of least

resistance for the electric current.

d

WARNING

d

Improper connection of the equipment grounding

conductor may result in electric shock. Have the

appliance checked by a qualified electrician or

service technician if you are in doubt as to whether

the appliance has been properly grounded.

Connecting the water

4.

A cold water connection is required for operation of

the automatic ice maker. The water pressure must

be between 25 and 120 p.s.i. (1.72ć8.25 bar).

The installation must comply with local plumbing

regulations.
A separate shutĆoff valve must be installed for the

appliance water connection.
The shutĆoff valve for the water connection must not be

behind the appliance. It is recommended to place the

shutĆoff valve directly next to the appliance (base unit)

or in another easily accessible location.
When installing the water connection, observe the

permitted installation areas for the pipe. For the

permitted installation areas and dimensions see

Installation dimensions", page 8.
The supply pipe can be located at the side on the right

(a), at the side on the left (b) or underneath (c).
Maximum outer diameter of the water pipe

(without fittings):

13

/

32

" (10 mm).

Attach a separate shutĆoff valve for the water

connection in a suitable, easily accessible location.

Do not use a selfĆpiercing valve!