Address Description Register

Value

40050

MSTR function (read)

2

40051

Error code

Read Only

40052

Number of consecutive registers to read

2

40053 Starting

register

1

40054

Destination node address

2

40055

Master node address

1

2. Set the middle portion of the MSTR instruction to 40100. This will be the

starting address of the MSTR Data Area. This is the location that will
contain the read data returned from the MSTR transaction.

Address Value

40100

Value of register 1 @ network address 2

40101

Value of register 2 @ network address 2

3. In this case, we are accessing two registers, so set the bottom portion of

the MSTR instruction (“number of registers”) to 2. In the case of MSTR
reads, this number cannot be greater than 125 by definition.

4. Initiate the read command by closing internal relay 1. The data response

will be seen in the MSTR Data Area (register 40100).


15.4 MSTR Write Example

The following example demonstrates how to use the MSTR instruction to write
4 registers starting at register 1 to an MBP-100 located at Modbus Plus network
address 32.

1. Set up a ladder logic program as shown in Figure 37.

2. Set the top portion of the MSTR Instruction to 40060. This will be the

starting address of the MSTR Control Block. Set the Control Block
registers to the following values:

Address Description Register

Value

40060

MSTR function (write)

1

40061

Error code

Read Only

40062

Number of consecutive registers to write

4

40063 Starting

register

1

40064

Destination node address

32

40065

Master node address

1

3. Set the middle portion of the MSTR instruction to 40200. This will be the

starting address of the MSTR Data Area. This is the location that will
contain the write data to be used in the MSTR write transaction.