Warning, For hvac installer only, Important – Therma-Stor Products Group UA-150H User Manual

Page 11

Advertising
background image

FOR HVAC INSTALLER ONLY

11

Ultra-Aire 150H Installer’s & Owner’s Manual

5. (DEH 2000) DIGITAL CONTROL

Installation Instructions

5.1 Specifications

Model: 4024539
Electrical: 24 VAC
Humidity Range: 20 – 90%
RH Humidity Accuracy: +/- 4%
Output: 3 Amps 24 VAC

5.2 Installation

This control panel must be installed in the conditioned space and
in accordance with all applicable codes and standards. Follow
the instructions below when installing and setting this control.

5.2A Install Instructions

1. Separate the front panel from the back panel by depressing

the tongue located in the bottom of the control.

2. Gently disconnect the quick connector on the back panel
3. Remove the battery from the back panel by sliding it to the left

and out from it’s retaining clip. To mount in the black battery
holder on the front panel, insert it from the top, gently pressing
downward until it snaps into place and is held under the top
clip of the holder. The + engraved on the battery should be
visible.

4. Line the back panel up against the wall or flat surface onto

which it is to be mounted and drill in the appropriate mounting
holes

5. Insert the screws so they extend approximately 1/8" from the

wall or flat surface.

6. Align the back panel against these screws, pushing it forward,

allowing it to slide downward to lock into position.

7. Make the electrical connections to the terminals on theback

panel as shown in the wiring diagram.

8. Seal the hole around the wires to prevent air movement.
9. Reconnect the quick connector onto the back panel.
10. Reassemble the front to the back panel. Connect at the top

first, then at the bottom.

5.2B Wiring

WARNING

Warning: Do not allow the yellow lead from the Ultra-Aire
to contact the red lead or orange lead from the Ultra-Aire or
damage to the transformer will result.

The installer must supply the wiring between the Ultra-Aire and
the control panel. Be sure to safely route the control wires to
prevent damage during installation. Be careful not to cross wires
when connecting the Ultra-Aire and the remote control panel or
damage to the transformer may result.

IMPORTANT

The remote controls of the
Ultra-Aire are powered by a
low voltage circuit (24 VAC)
and must NEVER contact or be
connected to a high voltage
circuit.

Some of the control wires may
not be used with certain control
panels and should be left safely
disconnected with wire nuts
taped onto the stripped ends. Be

sure to consult the electrical

schematic in this manual

before making the control

connections.

Figure 5:

Figure 6:

Figure 7: