Product specifications, Installation instructions, Warning – TriStar SP3210X15 User Manual

Page 5: Pump location, Pump mounting, Pipe sizing chart, Maximum recommended system flow rate by pipe size

Advertising
background image

WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

TriStar

Pump Series__________ _____ ______________________________ Page 5 of 15

Product Specifications

Installation Instructions

WARNING –

This product should be installed and serviced only by a qualified professional.

Pump Location

Locate filter as close to pool as practical and run suction lines as direct as possible to reduce friction
loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight
(but not over-tightened). Suction line diameter must equal or be larger than the discharge line diameter.

Though the filter is designed for outdoor use, it is strongly advised to place pump and filter in the shade

to shield them from continuous direct heat. Select a well-drained area that will not flood when it rains. Do NOT install
pump and filter in a damp or non-ventilated location.
Keep motor clean. Pump motors require free circulation of air for
cooling.

Pump Mounting


Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with screws or
bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid, and vibration free.

Pump mount must:

Allow pump inlet height to be as close to water level as possible.

Allow use of short, direct suction pipe (to reduce friction losses).

Allow for gate valves in suction and discharge piping.

Be protected from excess moisture and flooding.

Allow adequate access for servicing pump and piping.

Pipe Sizing Chart

* NOTE - It is recommended that a minimum length of straight piping (shown as “L” in above diagram), equivalent
to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.).

HP FR

“A” MR

“A”

½

13 5/8”

-

¾

13 7/8”

13 3/8”

1

14 3/8”

13 7/8”

1 *

14 3/8”

-

1 ½

14 7/8”

13 7/8”

1 ½ *

14 7/8”

14 3/8”

2

14 7/8”

15 1/8”

2 *

14 7/8”

14 7/8”

2 ½

-

14 7/8”

2 ½ *

-

14 7/8”

3

17 1/8”

15 5/8”

3 **

14 1/2”

-

MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE

Pipe Size

[mm]

Flow Rate

GPM [LPM]

Suction Pipe

Length *

Pipe Size

[mm]

Flow Rate

GPM [LPM]

Suction Pipe

Length *

Pipe Size

[mm]

Flow Rate

GPM [LPM]

Suction Pipe

Length *

1” [32]

20 [75]

5”

1 ½” [50]

45 [170]

7 ½”

2 ½” [75]

110 [415]

12 ½”

1 ¼” [40]

30 [110]

6 ¼”

2” [63]

80 [300]

10”

3” [90]

160 [600]

15”

* Two-Speed Pump
** Three-Phase

Pump

Advertising