Motor electric v/a, Full rate pumps, Warning – TriStar SP3210X15 User Manual

Page 6: Pump mounting (cont’d.), Plumbing, Electrical

Advertising
background image

WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

TriStar

Pump Series __________ _____ _______________________________ Page 6 of 15

Pump Mounting (cont’d.)


WARNING –

Hazardous Pressure. Pumps, filters, and other equipment/ components of a

swimming pool filtration system operate under pressure. Incorrectly installed and/or improperly tested
filtration equipment and/or components may fail resulting in severe personal injury or death.


Plumbing

Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly
cleaned before use. NOTE - Do NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic components.
When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting with one to two layers of
tape. Wind the tape clockwise as you face the open end of the fitting, beginning at the end of the fitting. The pump suction
and outlet ports have molded-in thread stops. Do NOT attempt to force hose connector fitting past this stop. It is only
necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and then use a tool to engage fitting an
additional 1 ½ turns. Use care when using Teflon tape as friction is reduced considerably; do NOT over-tighten fitting or
you may cause damage
. If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to two additional
layers of Teflon tape, and re-install connector.

Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings
that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and
Mechanical Officials (IAPMO) standards.

Use a non-entrapping suction fitting in pool (multiple drains) or double suction

(skimmer and main drain).

Electrical

WARNING –

Ground and bond motor before connecting to electrical power supply. Failure

to ground and bond pump motor can cause serious or fatal electrical shock hazard.

Do NOT ground to

a gas supply line.

To avoid dangerous or fatal electrical shock, turn OFF power to motor before

working on electrical connections.

Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical

problem. If GFCI trips and won’t reset, consult electrician to inspect and repair electrical system.

Fire

Hazard - match supply voltage to motor nameplate voltage.

Insure that the electrical supply

available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the HP

(kW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed
electrician, and MUST conform to local codes and NEC regulations.
Use copper conductors only.

Motor Brake Horsepower

Motor Rated Horsepower

Motor Electric V/A

Wire Size / Breaker

HP (kW)

HP (kW)

Voltage

Amps

AWG

Amps

1.13 (0.84)

0.50 (0.37)

208 - 230 / 115

5.3 - 4.9 / 9.8

14

10 / 15

1.39 (1.04)

0.75 (0.56)

208 - 230 / 115

7.0 - 6.2 / 12.4

14

10 / 15

1.85 (1.38)

1.00 (0.75)

208 - 230 / 115

8.5 - 7.4 / 14.8

14 / 12

15 / 20

2.40 (1.79)

1.50 (1.12)

208 - 230 / 115

11.2 - 10.2 / 20.4

14 / 10

15 / 30

2.70 (2.01)

2.00 (1.49)

208 - 230

11.8 - 11.0

14

15

3.60 (2.69)

3.00 (2.24)

208 - 230

16.0 - 14.8

12

20

3.60 (2.69) *

3.00 (2.24) *

208 - 230 / 460 *

9.6 - 9.4 / 4.7 *

14 *

15 / 10 *

1.85 / 0.22 (1.38 / 0.16)

1.00 / 0.12 (0.75 / 0.09)

208 - 230

8.6 - 8.2 ¹

14

15

2.40 / 0.28 (1.79 / 0.21)

1.50 / 0.18 (1.12 / 0.13)

208 - 230

11.4 - 10.4 ²

14

15

Full R

at

e Pumps

2.70 / 0.33 (2.01 / 0.25)

2.00 / 0.25 (1.49 / 0.19)

208 - 230

12.4 - 11.2 ³

14

15

0.94 (0.70)

0.75 (0.56)

230 / 115

5.4 / 10.8

14

10 / 15

1.25 (0.93)

1.00 (0.75)

230 / 115

7.0 / 14.0

14

10 / 15

1.65 (1.23)

1.50 (1.12)

230 / 115

7.7 / 15.4

14 / 12

10 / 20

2.20 (1.64)

2.00 (1.49)

230 / 115

10.8 / 21.6

14 / 10

15 / 30

2.60 (1.94)

2.50 (1.86)

230

11.5

14

15

3.45 (2.57)

3.00 (2.24)

230

13.5

14

15

1.85 / 0.22 (1.38 / 0.16)

1.50 / 0.18 (1.12 / 0.13)

208 - 230

8.6 - 8.2 ¹

14

15

2.40 / 0.28 (1.79 / 0.21)

2.00 / 0.25 (1.49 / 0.19)

208 - 230

11.4 - 10.4 ²

14

15

Ma

x Ra

te

Pum

ps

2.70 / 0.33 (2.01 / 0.25)

2.50 / 0.31 (1.86 / 0.23)

208 - 230

12.4 - 11.2 ³

14

15

¹

,

²

,

³ Low Speed Amps: (¹ 2.8 - 3.0) (² 3.2 - 3.4) (³ 3.8 - 4.1)

* Three-Phase (3Φ) Pump - motor starter required