d- Unit responds in an identical manner as the c command but does not clear the system
memory
E or e- Unit responds with minimum and maximums along with date and time of
occurrence. This uses the same buffer as the c and d command.
M- Unit responds with all term minimums and maximums with the date and time of their
occurrence, then clears.
m- Unit responds in an identical manner as with the M command but does not clear the
system memory.

Sample
TA 10:33 038F

TA 09:32 056 F

TI 04:15 075F

TI 15:03 080 F

TO 10:33 038F

TO 16:10 056 F

RH 15:44 033%

RH 01:40 060 %

BP 16:11 29.57”

BP 10:20 30.15"

RD 04/29 00:00“

RT 01:00"

RM

03.32“

WS 00:00 000 MPH 048

The system has two completely separate memory buffers (C and M commands). C is
cleared every midnight. M is only cleared by pressing the clear and min buttons on the
display or sending an upper case M via a computer.

R- Unit responds with current conditions. The rainfall rate is present rather than the term
rain. (Note: in 30.04R the “R” denotes rising pressure)
Sample
5:15 07/24/90 SSE 04MPH 052F 069F 078F 099% 30.04R 00.19"D 01.38"M 11.78"T
r- Unit responds with current conditions. The term rain is present rather than the
rainfall rate. (Note: in 30.04F the “F” denotes falling pressure, a “S” character
denotes steady pressure.)
Sample
5:15 07/24/90 SSE 04MPH 052F 069F 078F 099% 30.04F 00.19"D 01.38"M 00.72"R
K-

Unit responds with current calculated values for dew point, Windchill and heat
index.

Q- Unit response with hi resolution time, wind, temperature and pressure (in hi-res
models only).

Sample
96/01/15 09:21:44 SSE 004.3MPH 052.6F 069.2F 078.5F 069% 30.041F 002.19"

The following commands respond if the WRL has logged data in memory.
T- Data logger top, moves pointer to the top of the data records, then sends data
N- Data logger next, moves pointer to the next data record, then sends data.
A- Data logger again, sends same data again.
P- Data logger previous, moves pointer to the previous data record, then sends
data.
B- Data logger bottom, moves pointer to the bottom of the data records.
Sample
96/03/07 23:00 056.2F 053.2F 085.8F 070% 29.926I" 00.00"ID 007.5MPH 342D