AT Commands

Table A-7. Result Codes

Number

Word

Description

0

OK

The OMEGA CDMA Modem executed a command line without
errors.

1

CONNECT

The OMEGA CDMA Modem has made a data connection with
another modem.

2

RING

The OMEGA CDMA Modem has detected an incoming call.

3

NO CARRIER A carrier from the remote modem was lost or was not present.

4

ERROR

The OMEGA CDMA Modem found an error in your typed
command line.

6 NO

DIALTONE

The OMEGA CDMA Modem did not detect a dial tone before the
timeout period specified by Register S7 elapsed (default time is
50 seconds).

7

BUSY

The OMEGA CDMA Modem has detected a busy signal.

8

NOANSWER

Five seconds of silence were not detected after a ring.

Using S-Registers

S-Registers are addresses of places in memory where various timing parameters, redefinitions of
selected ASCII characters, and other configuration settings are stored. The OMEGA CDMA
Modem provides S registers for setting modem configuration parameters and establishing
modem default behavior. To display S-Registers, use the command ATSr?, where r is the
register’s number. For example, issuing the command ATS0? displays the contents or setting for
S-Register 0.

To set an S-Register value, use the command ATSr=n, where r is the register’s number and n is
the new register value. For example: issuing the command ATS0=2 changes the setting for S-
Register 0 to 2. This setting tells the OMEGA CDMA Modem to automatically answer incoming
calls after the second ring.

Note:

If you do not write an S-Register setting with &W, the setting will be retained
only until the next reset or power off.