Configuration pre-check, Remove the 10 screws securing the cover on the box, Lift the cover off – Telex SS-1002 User Manual

Page 9: Dip switches, Installation

Advertising
background image

7

CHAPTER 2

Installation

Configuration Pre-check

Before making connections, read the following configuration notes. Make sure all internal controls are properly set for your
intended usage.

To access the internal controls, do the following:

1.

Remove the four (4) screws on the front panel that secure the intercom station faceplate to the mounting box.

2.

Pull the faceplate out for all versions (except the RM version).

To access the internal controls for the RM version, do the following:

1.

Remove the 10 screws securing the cover on the box.

2.

Lift the cover off.

DIP Switches

TABLE 1.

DIP Switch descriptions and factory default settings

Switch

Number

Description

Settings

Open = OFF; Closed = ON

Default

Settings

1

Mic Kill Receive

Closed: Disabled, No Mic Kill
Open: Enabled, Mic Kill Active

Open

2

Call Signal Method

Closed: DC (SW1 set to UNBAL)
Open: Audiocom (SW1 set to BAL)

Open

3

Incoming Call Beep

Closed: Disabled
Open: Enabled

Open

4

Microphone Type

Closed: Unbalanced
Open: Balanced

Open

5

Speaker Beep for Incoming
Call

Closed: Enabled (DIP switch 3 must be set to Open)
Open: Disabled

Open

6

Not Used

Not Defined

Open

7

Not Used

Not Defined

Open

8

Not Used

Not Defined

Open