Texas Instruments WR-25 User Manual

Page 14

Advertising
background image

Inx Value Description

Inx Value Description

1

85 temp:aux

20

94 clock years

2

65 temp: inside

21

11 clock month

3

73 temp: outside

22

22 clock day of month

4

29.92 barometric pressure

23

2 clock day of week::Mon:

5

0 elevation

24

11 clock hours

6

0.750 MVP @ 0.0% HR

25

24 clock minutes

7

3.255 MVP @ 73.3% HR

26

54 clock seconds

8

8 wind dir. offset

27

0 log interval hrs

9

2 rain inc flag

28

30 log interval minutes

10 0.01 rain inc value

29

0 Scale: 0=FPS 1=CGS

11 0.00 rain fall: daily

30

0 ID number

12 0.00 rain fall: monthly

31

8 POR Counter

13 0.00 rain fall: term

32

0 RR Interval , sec

14 0 report interval HI

33

0 Wsp units : MPH

15 0 report interval LO

34

1 Time dispaly : AMPM

16 0 report Min/Max :Off

35

1 aux Temp

17 4 report end of day

36

1 Wsp/Wdir

18 0 report interval Units: M:S:

37

4 baud rate: 2400

19 0 report character: r

38

enter parameter index: ?

Note: This screen and its index numbers will vary depending on what options are installed.

Any item in this index can be changed by:
(1)entering the index number
(2)entering the new value
(3)entering Y to set the new value or N to reject the new value.
1) Aux temperature calibration
2)

Inside temperature calibration

3)

Outside temperature calibration

4)

Barometric pressure calibration

5) Elevation correction ( not used)
6)1st

humidity sensor calibration factor

7) 2nd humidity sensor calibration factor
8)

Wind direction calibration

, increase number to move clockwise or decrease number to move

counterclockwise.
9)

Rain collector type

(most rain collectors are type 2 including TWI, 0 turns of the rain collector

counter)
10)

Rain increment value

( the value that is added for each click of the

rain collector

, most rain

collectors should be set for 0.01 including TWI)
11)

Daily rainfall history register

12) Monthly rainfall history register
13)

Term rainfall history register

14)

Report output interval HI

, sets the automatic data dump interval to the RS232. Value can be in

WR-25 Instruction Manual

Texas Weather Instruments, Inc. WR-25 Instruction Manual