Installing network cable – Transition Networks LAN MASTER 33022.B User Manual

Page 10

Advertising
background image

LANMaster™ T8

8-Port Ethernet™ Repeater Hub

12

7

Installing Network Cable

10BASE-T Requirements

STRAIGHT-THROUGH/CROSSOVER CABLE/CONNECTOR

NOTE: The 10BASE-T cable and RJ-45 jacks for hub to terminal device
connections must be configured as straight through. The 10BASE-T
cable and RJ-45 jacks for hub to hub connections must be configured
as crossover.

The “X” port provided on the LANMaster T8 changes a physical
straight through cable configuration to a logical crossover cable
configuration for hub to hub connections.

Therefore, ensure that all 10BASE-T cable to be installed is straight-
through:

Straight Through Cable

at RJ-45 Plug

Hub . . . . . . . . . . . . . . . .PC, transceiver, NIC, printer

RJ-45 Male . . . . . . . . . . . . . . .RJ-45 Male

1 . . . . . . . . . . . . . . . . . . .1
2 . . . . . . . . . . . . . . . . . .2
3 . . . . . . . . . . . . . . . . . .3
6 . . . . . . . . . . . . . . . . . . .6

RJ-45

P

LUG

1

8

2 3 4 5 6 7

RJ-45

J

ACK

1

8

Installing Thinnet 10BASE-2 Cable

The LANMaster T8 has a female BNC MDI connector installed at the
back for connection to 10BASE-2 cable and comes with a mating T-
connector and a 50-ohm segment terminator for making the cable
connection.

To connect to 10BASE-2 network cable:

1. Locate or build IEEE 802.3 compliant 10BASE-2 cable with

male BNC connectors installed at both ends.

2. Install the mating T-connector to the female BNC connector on

the LANMaster T8.

3. Install 10BASE-2 cable to one side of the T-connector.

4. Install 10BASE-2 cable to other side of the T-connector

OR, if the LANMaster T8 is the last network device in the daisy
chain, install a 50-ohm terminator.

5. Verify that the 10BASE-2 segment coax cable segment is

terminated properly at both ends.

In a coax thinnet
installation, the first and
last device in the daisy-
chain must be
terminated with a 50
ohm terminator.
Additionally, the
10BASE-2 segment must
be grounded to “earth
ground” at one end.

50 ohm terminator

50 ohm terminator

earth ground

The two active pairs in a
10BASE-T network are pins 1 & 2
and pins 3 & 6. Use only
dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange) for
the active pins.